This research aims to study the application of kaolin with coconut fiber corncobs fiber and durian peel in concrete masonry unit wall for increasing effective heat protection and lightweight. The ratio of cement type 1: kaolin is equal to 1: 60 by weight. The kaolin is replaced by fiber include coconut fiber corncob fiber durian peel fiber with 1.67% 3.33% and 5% by weight of kaolin. The kaolin concrete block mixed with fiber sample size is formed to 6.9 x 39 x 19 centimeter with the hydraulic compactor. The samples tested in physical and mechanical properties follow the TIS 58-2533 standard. Resulting their fibers can reduce the density thermal conductivity and compressive strength and increase the changing length and water absorption of kaolin concrete blocks. The kaolin concrete block without fiber has highest compressive strength followed by the kaolin concrete block mixed with corn cob fiber the kaolin concrete block mixed with coconut meal fiber and the kaolin concrete block mixed with durian peel fiber has lowest compressive strength respectively. However their fibers have possibility to be composite materials to reduce weight of kaolin concrete blocks

2558
การวิเคราะห์แรงดันเกินในระบบกราวด์ ของสถานีไฟฟ้าสูงโดยใช้โปรแกรมเอทีพี/อีเอ็มทีพี
การวิเคราะห์แรงดันเกินในระบบกราวด์ ของสถานีไฟฟ้าสูงโดยใช้โปรแกรมเอทีพี/อีเอ็มทีพี

The analysis of the grounding system overvoltage in High voltage substation will be held at Bumnetnarong substation Electricity Generating Authority of Thailand ( EGAT ) by using ATP draw for grounding system’s model of substation also to model overvoltage from lightning and to read the result of overvoltage from differences positions. The advantages of the experiment are to be educated and to who design Grounding system in high voltage substation EGAT. The Study’s result of the over voltage level on Ground Potential Rise: GPR model shows that the pie will show close result to the result from the calculation by standard IEEE Std 80-2000 and the result of the Fault Current at the middle position of the grounding system will result in higher overvoltage than at the result at the corner position of Grounding system. The result of Ground Resistance: Rg shows that the increasing of overvoltage the increasing of Ground Resistance: Rg

2553