การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า
การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า

This thesis presents the combined loss reduction approach to apply in distribution system. The thesis objective reduces the loss in the distribution system when all voltage magnitude levels at connection points must under the limits. Therefore the Simulated Annealing Technical selects as searching tool to find the suitable location of DG and Capacitor. The propose technique applies to the distribution system 69 buses model. The results shown that this technique can reduce in power losses from properly organize the location of DG and Capacitor. Moreover it can also balance and increase the voltage levels. The propose Simulated Annealing Technical is used to determine and organize the sectionalizing and tie switches in the feeder which installs DG and Capacitor by considering the power losses and the number of time to change the status of disconnecting switches.

2564
การวิเคราะห์ผลทางเศรษฐศาสตร์สำหรับติดตั้งสถานีจำหน่ายไฟฟ้าย่อย
การวิเคราะห์ผลทางเศรษฐศาสตร์สำหรับติดตั้งสถานีจำหน่ายไฟฟ้าย่อย

This research study is the application of Geographic Information System (GIS) for distribution substation. The main purpose is to satisfy user by planning to support the increase of load at present and in the future. Moreover increase in creditability of distribution system by increasing new substation or expand the area of exist substation. Then Geographic Information System is necessary for the mentioned reason. Geographic Information System is the process of geographical data in computer system that defined useful information and related to spatial data such as residential property house number location latitude and longitude. Geographic Information System consists of capture store manipulate analyze manage and present all types of geographical data according to user’s objective. So Geographic Information System is the utility that be useful for distribution substation project. The research is planning to use Geographic Information System for finding Break-even point between increasing new substation or expand the area of exist substation which is 2 case studies.

2563
การประเมินผลกระทบของการลัดวงจรในระบบจำหน่ายไฟฟ้าที่มีต่ออุปกรณ์วิกฤต
การประเมินผลกระทบของการลัดวงจรในระบบจำหน่ายไฟฟ้าที่มีต่ออุปกรณ์วิกฤต

This research presents the studying of short circuit in distribution system that affect to critical equipment voltage sag and overvoltage while short circuit event. Lead into the quality of electric user. Effect on economics damaged Distribution system voltage level 22kV of The Provincial Electricity Authority. It is the analysis model by computer program. The event of short circuit set in a many distribution systems. The analysis result Magnitude of voltage while short circuit bring to assessment voltage sag and overvoltage from average voltage of the repeat event. Then set boundary of voltage at load point in a many. The experiment shows the problem of the quality of electric be affect to critical equipment less than load point close connection with substation.

2563
ความสัมพันธ์ของการกระจายตัวของสารป้องกันกำจัดศัตรูพืชตกค้างในดินเพาะปลูกข้าวและระดับการปนเปื้อนในเมล็ดข้าว
ความสัมพันธ์ของการกระจายตัวของสารป้องกันกำจัดศัตรูพืชตกค้างในดินเพาะปลูกข้าวและระดับการปนเปื้อนในเมล็ดข้าว

The effect of pesticides on farmers and the distribution of residual pesticides in rice plants and rice grain was studied in rice farming area covered in Samchuk district Suphanburi province. The situation and health effects related to pesticides was conducted using an individual interview and filled-form questionnaire with 126 samples. The participants were male of 68.3% and female of 31.7%. Educational level of participants was to be 36.5% and 24.6% for primary and elementary levels respectively. One-third of farmers (33.3%) reported a monthly income in the range of 5000 to 10000 Baht. A quarter of farmers (25.4%) got higher a monthly income with 10001 to 15000 Baht. Family members was found to be 4 persons (54%) 5 persons (19.8%) and over 5 persons (11.1%). All participants concerned the behavior and perception related pesticides for their highly toxicities and extremely dangerously death. A half of herbicide (50%) was glyphosate. Seriously paraquat (commercial name of Gramoxone) was found to be 22%. On the other hand the most of insecticide (55%) was an abamectin and carbofuran (commercial name of Furadan) was found to be 15%. A 20 samples of rice plants and rice grain was collected by random sampling. The residual carbofuran and glyphosate in rice plants and rice grain was determined using standard method. It was found that carbofuran was found in the range of ND-0.05 μg/kg and ND-0.08 μg/kg for rice plants and rice grain respectively. Glyphosate was found in the range of ND-0.26 μg/ kg and ND– 0 . 2 2 μg/ kg for rice plants and rice grain respectively. The residual levels of carbofuran and glyphosate in rice plants and rice grain depended on a spray period time their decomposition and the concentration of carbofuran and glyphosate. The residual levels of carbofuran and glyphosate did not significantly quantitative correlation between rice plants and rice grain.

2563
การออกแบบกราวด์กริดของสถานีจำหน่ายไฟฟ้าย่อย โดยมีสองสถานีในบริเวณเดียวกัน
การออกแบบกราวด์กริดของสถานีจำหน่ายไฟฟ้าย่อย โดยมีสองสถานีในบริเวณเดียวกัน

Ground grid design of substation is very important. It will help prevent the danger caused by the fault which causes the high step voltage and high touch voltage and may cause the operator to die. It also helps prevent damage to equipment and increases reliability for power systems as well. Currently the Gas Insulated Substation (GIS) has been built a lot especially in areas with limited space because it takes less space than the Air Insulated Substation (AIS). In order to create a substation of the GIS model instead of the AIS model. In order to create the GIS instead of AIS including the improvement or maintenance of the substation it is necessary to build another small substation to supply electricity to replace electricity from the original substation. However there are two substation stations in the same area may cause an increase of high-slope ground potential between the ground grid systems of both substations. It will cause high step voltage and high touch voltage while the fault is diminished. Therefore before improvement or maintenance of substation the ground grid distance and the size of the newly constructed substation must be analyzed that what effect on step voltage and touch voltage generation. Including studying the effects of step voltage and touch voltage that will occur.