จำนวน Repository ( 13 )
การวิเคราะห์คุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าที่มีแหล่งผลิตไฟฟ้าพลังงานลม
This Thesis presents an analysis of wind turbines in a power distribution system that has a wind power source. By comparing the wind turbine with 3 blades and 4 wind turbines while there is no distribution in the distribution system. And the load is distributed in the distribution system To analyze the differences of these 2 wind turbines analyze the pressure values The power quality in the distribution system that occurs. And able to apply wind turbine energy for sustainability And practices to support the correct power supply In the distribution system and able to provide electricity with efficiency and reliability Wind turbine when connecting to the electricity distribution system There is a significant impact on the power distribution system such as the impact on the power loss. Pressure impact etc. It can be seen that the wind turbine with 3 blades works less than the wind turbine with 4 blades not so much. Therefore the test shows that the analysis of the electricity quality in this distribution system for use as a case study And continue to improve the production of wind turbines in the electricity distribution system.
เทคนิคการจัดเรียงสายป้อนและการกำหนดตำแหน่งตัวเก็บประจุในระบบจำหน่ายไฟฟ้าเพื่อทำให้ค่าดัชนีโหลดสมดุลต่ำสุด
This paper presents an efficient algorithm for optimization of radial distribution systems by a feeder reconfiguration to balance feeder loads and eliminate overload conditions. The system load-balancing index is used to determine the loading conditions of the system and maximum system loading capacity. The index value has to be minimum in the optimal feeder reconfiguration of load balancing. A method based on Tabu search algorithm The Tabu search algorithm is employed to search for the optimal feeder reconfiguration. Simulation results for a radial 69-bus system with reconfiguration and capacitors placement. The study results show that the distribution system with capacitor placement and optimal on/off patterns of the switches feeders reconfiguration can be load balancing in distribution systems.
การวิเคราะห์แรงดันตกชั่วขณะเมื่อมีการติดตั้งแหล่งผลิตไฟฟ้าแบบกระจายตัวในระบบจำหน่าย
This research presents an Analysis of Voltage Sags on the Installation of Distributed Generation in the Distribution System. The computer program PSCAD/EMTDC (Power Systems Computer Aided Design / Electromagnetic Transient in DC system) version 4.2 is applied to provide electrical parameters for the modeling and simulation and to analyze the fault occurred which resulted in voltage sag. Test results from PSCAD/EMTDC show the values of voltage sag when 5 types of fault are occurred (Single Line to Ground Fault Double Line to Ground Fault Three Phase to Ground Fault Line to Line Fault and Three Phase Fault). For all cases the value of root mean square voltage before fault is 100% or 1.0 pu. It can be seen that for both radial line and closed circuit when DG are installed in the system the value of phase to ground RMS residual voltage and phase to phase RMS residual voltage at the bus of Bang-pa-in 2 substation are more than the values in case of the system without DG.
การติดตั้งแหล่งผลิตไฟฟ้าแบบกระจายตัวเพื่อเพิ่มความเชื่อถือได้ในระบบจำหน่ายไฟฟ้า
This paper presents reliability evaluation in distribution system with distributed generation. The main objective is to minimize the customer interruption cost subject to given number of distributed generation. The minimization problem for customer interruption cost in solved by the developed tabu search algorithm together with reliability worth analysis that provide an indirect measure for cost implication associated with power outages. The developed methodology is tested with a distribution system of Roy Billinton Test System (RBTS) bus 2 consist of 15 buses and 22 load points. Numerical results from the tests demonstrate that the optimal distributed generation placement can be used to promote reliability of the distribution systems.
การประเมินคุณภาพไฟฟ้าในระบบจำหน่ายที่จ่ายไฟให้พื้นที่นิคมอุตสาหกรรม
This paper presents an assessment of the quality of electricity transmission and distribution system to supply power to the industrial area. The objective is to analyze the power quality that customer in the industrial area need high level. By analyzing the power quality of Provincial Electricity Authority (PEA) in transmission system 115 kV distribution system 22 kV and 400/230 volt in Rojana industrial park from power quality meters. The study concluded that the phenomenon occurs continuously consist of RMS voltage power frequency voltage unbalance short term flicker long term flicker Harmonic meet the standards applied to all. The phenomenon occurs temporary consist of transient voltage dip voltage swell interruption in the conclusion the power quality problems caused by voltage dip most especially with loads which are sensitive to voltage. From the moment the measurement showed that the voltage dip on transmission system 115 kV maximum of 19 times. The voltage dip that occur including three voltage level of 30 times there are events that do not pass SEMI F47 standard 12 times or 40%.