จำนวน Repository ( 13 )
การวิเคราะห์ค่าความเป็นฉนวนของบุชชิ่งหม้อแปลงไฟฟ้าแรงสูง
This article presents how the analysis an insulation of high voltage transformer bushing. The purpose is to analysis the moisture in the bushing to evaluate the approach for maintenance. The analysis rely on the principle of the Polarization and Depolarization Current (PDC) technique which is a technique for analyzing the insulation of high voltage equipment to test high voltage transformer bushing for a case study. This method is performed by energize 1000 Vdc into a bushing in period of time and then switch off the circuit for discharge current. Finally we calculate the moisture of main insulation of high volt bushing as well compare with standard moisture of criteria. The method is useful of preventive maintenance plane of high volt bushing and reduce the failure in the power system.
การสร้างระบบการจัดการความเสียหายหม้อแปลงไฟฟ้ากำลังด้วยวิธีการจัดการอุตสาหกรรมอย่างยั่งยืน กรณีศึกษา บริษัท ถิรไทย จำกัด (มหาชน)
This research aimed to establish the power transformer fault management system by applying Sustainable Industrial Management Engineering (SIME.) method. The research tools were electrical and chemical testing. As power transformer is usually huge when it is damaged the possible way to manage such damage is to send such power transformer to the manufacturer’s plant for repair which requires long period of time and high costs of repair. As a result the researcher therefore establish the power transformer fault management system as a tool for assessing damage to decide whether power transformer repair should be instead done at the power station or not in order to decrease the number of power transformer returned to the manufacturing plant for repair. This would eventually help reduce costs and time for repairing power transformer and allows faster period of reuse of power transformer concomitantly. According to the result it would found that the power transformer fault management system by applying Sustainable Industrial Management Engineering (SIME) method could be used as guidance for decision making to have power transformers repaired at the power station as much as possible. This could help reduce average time spent for repair by 84.44 percent with the cost reduction by 68.62 percent when comparing to returning power transformers to the manufacturing plant. This could also be applied in planning for power transformer maintenance prior to the occurrence of any damage to power transformers further.
Technique to Resolve the Leakage for Pressure Relief Oil of Transformer 300 MVA
Today Transformers 300 MVA in use of Electricity Generating Authority of Thailand Metropolitan Electricity Authority and private companies were active in the power transmission system. To increase the efficiency and security of the countrys energy systems after using it for a while it requires annual maintenance such as checking and testing of various power. However the problem of leakage of transformer oil is a common problem and affects the environment. This is caused by the malfunctioning equipments which affect the performance of the transformer. The solution will require more time and money. We have to find a way to fix the leak of the transformer oil by reducing the amount of oil and the temperature of the oil in order to reduce the time and cost -savings.HoweveriIt does not affect the performance of the transformer
Design and construction tesla transformer 120 kV 120 kHz for Insulator Testing
This research presented the details of design and constructions of tesla transformer for testing insulator. The out put of the tesla transformer has a rate of 120 kV and 120 kHz. Tesla transformer consisted of primary coil and secondary coil which is wound on a PVC insulating chamber and use air insulation in part of coaxial. The Rotary Gap is rotated eletrode which use for increasing efficiency of voltage generation. This paper presented the details of design and constructions are explained. And compare the tesla Transformer reproduce which is created the voltage at 120 kV and frequency 120 kHz for used in HighVoltage Laboratory Faculty of Engineering Rajamangala University of Technology Para Nakhon.
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz
This project design and constructions high voltage high frequency transformer or tesla transformer. The tesla transformer is design at 500 kV rating voltage and 250 kHz resonant frequency. By coupling air axle and have the air are the electric insulator between primary coil and secondary coil Which primary coil test at 60 degree Group part spark gap is will the Electrostatic gap. This paper propose and consider high voltage high frequency transformer at 500 kV and 250 kHz rated. For use a transformer aforementioned is the equipment for test flash over prenouaena of porcelain insulator and electric insulation.