จำนวน Repository ( 9 )

Fluctuation Voltage Control of Wind Turbines via STATCOM
Fluctuation Voltage Control of Wind Turbines via STATCOM

This paper presents distributed STATCOM for controlling voltage in distribution line with wind turbines generations at 48 volts. The connection of wind turbine to distribution systems may affect the voltage quality offered to the consumers. One of the factors contributing to this effect is the rapid variations of the wind turbine output power which cause respective fluctuations in the supply voltage. This paper presents the design control and analysis of a Distributed STATCOM when combined with a wind turbine comprising small variable speed generators in this paper it is shown that the distributed STATCOM controlled via a rotating referent frame: RRF and recursive DFT are simple method to DSP control technique. The result of experiments the STATCOM can improve the transient stability voltage of wind turbine that we have referred the IEEE1159:1995 standard of power quality.

2553
การวิเคราะห์ศักยภาพพลังงานลมและข้อมูลลมรายปีบริเวณพื้นที่ อำเภอสะเมิง จังหวัดเชียงใหม่
การวิเคราะห์ศักยภาพพลังงานลมและข้อมูลลมรายปีบริเวณพื้นที่ อำเภอสะเมิง จังหวัดเชียงใหม่

In this study the wind speed characteristic and evaluation of wind power generation at Samoeng district Chiang Mai were investigated using wind speed data and wind direction data during time of January 2011 to December 2011 and measured at a height of 20 40 and 80 m above ground level. It was found that the mean wind speed of 3.8 3.92 and 4.30 m/s. While the mean wind direction of 20.73% and indicating from the southwest. The mean of power density of 107 W/m2 the shape parameter (k) was 1.715 1.633 and 1.783 scale parameter (c) of 3.649 3.651 and 4.092 m/s the mean of wind shear coefficient was 0.19. The evaluation of wind energy for electricity generation by install the wind turbine of Nordex N50 from Germany and Vestas V90 from Denmark were capacity of 800 kW and 3 MW. It could produce annual electricity of 1761379 kWh and 3772400 kWh and the capacity factor show 25.13% and 14.35% respectively. Finally the results showed the northern area of Thailand was suitable for wind power development in further.

2565
การวิเคราะห์คุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าที่มีแหล่งผลิตไฟฟ้าพลังงานลม
การวิเคราะห์คุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าที่มีแหล่งผลิตไฟฟ้าพลังงานลม

This Thesis presents an analysis of wind turbines in a power distribution system that has a wind power source. By comparing the wind turbine with 3 blades and 4 wind turbines while there is no distribution in the distribution system. And the load is distributed in the distribution system To analyze the differences of these 2 wind turbines analyze the pressure values The power quality in the distribution system that occurs. And able to apply wind turbine energy for sustainability And practices to support the correct power supply In the distribution system and able to provide electricity with efficiency and reliability Wind turbine when connecting to the electricity distribution system There is a significant impact on the power distribution system such as the impact on the power loss. Pressure impact etc. It can be seen that the wind turbine with 3 blades works less than the wind turbine with 4 blades not so much. Therefore the test shows that the analysis of the electricity quality in this distribution system for use as a case study And continue to improve the production of wind turbines in the electricity distribution system.

2563
Development of Smart Monitoring System for Wind Energy System
Development of Smart Monitoring System for Wind Energy System

The paper presents a development of monitoring system for a prototype wind turbine system. The proposed monitoring system is developed under Labview environment. The system can connect to the wind turbine online via internet. The system will collect the monitored values and install values into memory. Simultaneously the system can show the values in Real-Time. The operator can observe the wind turbine by the monitoring system and can take an action on time if the wind turbine is not working properly. The results of the monitoring system indicate that the monitoring system is be able to working properly the data can be used to investigate the wind turbine for system analysis. This is very important for wind turbine in order to supply energy to consumer stably.

2553