จำนวน Repository ( 22 )

จักรยานออกกำลังกายผลิตไฟแบบ ON-GRID
จักรยานออกกำลังกายผลิตไฟแบบ ON-GRID

This Project presents electric bicycle. The structural feature is the use of the bicycle to be modified as it is designed to spin the rotor of the 5-phase magnetic line generator set and test the voltage distribution. The principle of operation of electric bicycles relies on the mechanical energy gained from cycling. The rotor consists of a series of permanent magnetic poles intersecting with a stator consisting of a set of conductor coils generating an AC voltage and converting it from AC to DC through a diode bridge to obtain DC voltage. To be connected to the boost converter to increase the output side pressure level to get the right voltage to charge a 12 volt battery. batteries. The test has been tested for cycling to generate electricity at a speed of 400 rpm while no-load has a voltage of 23.3 volt and with a load per load and at a speed of 400 rpm the voltage is 12.1 volt If the bicycle is cycled at an increased speed the voltage and current will increase. In order to transmit electric power to the single-phase power system an inverter is used to connect the single-phase power system to transmit to the single-phase power grid.

2566
การแปลงหน้าที่ทางคุณภาพเพื่อพัฒนาผลิตภัณฑ์ผลิตไฟฟ้าจากลมระบายความร้อนของเครื่องปรับอากาศ
การแปลงหน้าที่ทางคุณภาพเพื่อพัฒนาผลิตภัณฑ์ผลิตไฟฟ้าจากลมระบายความร้อนของเครื่องปรับอากาศ

This research had the objective to design and develop power production from daily life leftovers for their highest benefit of utilization by using the principle of quality function development and power generator that changed mechanical energy into electric energy. In developing electric generator product from air conditioner condensing unit the researcher found that there were 4 important factors including speed installation distance size and cross-sectional area of the fan and the test was conducted between 8.00-17.00 hours. The researcher collected the data and analyzed the test result and found that the best result in the test was to install the product at the distance of 10 cm by using an 18 fan in order to acquire the best voltage and the data were collected so that they could be implemented in developing such product in the future.

2566
การวิเคราะห์ศักยภาพพลังงานลมและข้อมูลลมรายปีบริเวณพื้นที่ อำเภอสะเมิง จังหวัดเชียงใหม่
การวิเคราะห์ศักยภาพพลังงานลมและข้อมูลลมรายปีบริเวณพื้นที่ อำเภอสะเมิง จังหวัดเชียงใหม่

In this study the wind speed characteristic and evaluation of wind power generation at Samoeng district Chiang Mai were investigated using wind speed data and wind direction data during time of January 2011 to December 2011 and measured at a height of 20 40 and 80 m above ground level. It was found that the mean wind speed of 3.8 3.92 and 4.30 m/s. While the mean wind direction of 20.73% and indicating from the southwest. The mean of power density of 107 W/m2 the shape parameter (k) was 1.715 1.633 and 1.783 scale parameter (c) of 3.649 3.651 and 4.092 m/s the mean of wind shear coefficient was 0.19. The evaluation of wind energy for electricity generation by install the wind turbine of Nordex N50 from Germany and Vestas V90 from Denmark were capacity of 800 kW and 3 MW. It could produce annual electricity of 1761379 kWh and 3772400 kWh and the capacity factor show 25.13% and 14.35% respectively. Finally the results showed the northern area of Thailand was suitable for wind power development in further.

2565
การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า
การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า

This thesis presents the combined loss reduction approach to apply in distribution system. The thesis objective reduces the loss in the distribution system when all voltage magnitude levels at connection points must under the limits. Therefore the Simulated Annealing Technical selects as searching tool to find the suitable location of DG and Capacitor. The propose technique applies to the distribution system 69 buses model. The results shown that this technique can reduce in power losses from properly organize the location of DG and Capacitor. Moreover it can also balance and increase the voltage levels. The propose Simulated Annealing Technical is used to determine and organize the sectionalizing and tie switches in the feeder which installs DG and Capacitor by considering the power losses and the number of time to change the status of disconnecting switches.

2564
การศึกษาสมรรถนะของโรงไฟฟ้าไตรแลทเทอร์รัล ซับคริติคัล โออาร์ซี และซุปเปอร์คริติคัล โออาร์ซี โดยใช้แหล่งความร้อนใต้พิภพเป็นแหล่งพลังงาน
การศึกษาสมรรถนะของโรงไฟฟ้าไตรแลทเทอร์รัล ซับคริติคัล โออาร์ซี และซุปเปอร์คริติคัล โออาร์ซี โดยใช้แหล่งความร้อนใต้พิภพเป็นแหล่งพลังงาน

This study investigates three different types of power plant include a trilateral cycle (TLC) subcritical organic Rankine cycle (ORC) and supercritical ORC power plant driven by geothermal heat source with mass flow rate 1 kg/s and temperature of 100๐C 110๐C and 120๐C. with 27 substances were examined as the working fluid of the power plant. While the net power output of 4.78 kW and 7.74 kW is obtained from the subcritical ORC with RC318 as its working fluid when the heat source temperature are at 100๐C and 110๐C respectively. Meanwhile the net power output of 11.85 kW is obtained from the subcritical ORC with R227ea as its working fluid when the heat source temperature is at 120๐C. The net power output of 5.64 kW and 9.16 kW are obtained from the supercritical ORC with R218 as its working fluid when the heat source temperature are at 100๐C and 110๐C respectively. Meanwhile the net power output of 12.88 kW is obtained from the supercritical ORC with R143a as its working fluid when the heat source temperature is at 120๐C. Furthermore the net power output of 7.96 kW 12.27 kW and 17.38 kW are obtained from the TLC plant with heptane as its working fluid when the heat source temperature are at 100๐C 110๐C and 120๐C respectively.

2564