จำนวน Repository ( 11 )

Design and development of calculation program for magnetic fields intensity of high voltage transmission and distribution lines
Design and development of calculation program for magnetic fields intensity of high voltage transmission and distribution lines

This paper presents a program developed for calculating magnetic field intensity of high voltage transmission line and high voltage distribution lines. This program was developed with Microsoft Visual Basic and Microsoft Access program was used to store the database of the peak ratings current height and space of transmission lines. The developed program was able to calculate magnetic field intensity of high voltage transmission line and high voltage distribution lines according to 2 standards of Provincial Electricity (PEA): “A 22 kV Single Conductor Circuit High Voltage Distribution System” and “115 kV Single Conductor Circuit High Voltage Transmission System”. The program was able to select structure of the electrical system to be calculated as well as types and specification of Transmission line from the stored database that corresponded with the structure. The calculated output waveforms were displayed on computer monitor. Results from the developed program enable more convenient and faster calculations of magnetic field intensity of high voltage transmission line and high voltage distribution lines and are useful for analysis of possible impacts on electric and electronic devices.

2558
การวิเคราะห์แรงดันเกินในระบบกราวด์ ของสถานีไฟฟ้าสูงโดยใช้โปรแกรมเอทีพี/อีเอ็มทีพี
การวิเคราะห์แรงดันเกินในระบบกราวด์ ของสถานีไฟฟ้าสูงโดยใช้โปรแกรมเอทีพี/อีเอ็มทีพี

The analysis of the grounding system overvoltage in High voltage substation will be held at Bumnetnarong substation Electricity Generating Authority of Thailand ( EGAT ) by using ATP draw for grounding system’s model of substation also to model overvoltage from lightning and to read the result of overvoltage from differences positions. The advantages of the experiment are to be educated and to who design Grounding system in high voltage substation EGAT. The Study’s result of the over voltage level on Ground Potential Rise: GPR model shows that the pie will show close result to the result from the calculation by standard IEEE Std 80-2000 and the result of the Fault Current at the middle position of the grounding system will result in higher overvoltage than at the result at the corner position of Grounding system. The result of Ground Resistance: Rg shows that the increasing of overvoltage the increasing of Ground Resistance: Rg

2553
Design and Construction of High Voltage Diode 100 kV
Design and Construction of High Voltage Diode 100 kV

Diode high voltage the equipment assembles. That have necessity and important for a room practices for test experiment research and for the instruction. But diode high voltage to bring an element in a room practices something still must buy from the foreign countries and expensive. This problem corrects by designing and establish by oneself. This project has designed and build to diode high voltage for a laboratory by diode high voltage 100 kV. That can bring assemble all circuit get the circuit voltage multiplier etc. Building from the inventory at can seek can buy in house diode high voltage. That design and build that is the series diode on print circuit and electric oil insulator. Base principle of diode data technical of the components for applies in designing. The way builds to diode high voltage diagnose of designing builds consider the test diode high voltage the office designs. Which test has followed the objective is pass the power frequency withstand voltage test 120 kV 22 mA

2553
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz

This project design and constructions high voltage high frequency transformer or tesla transformer. The tesla transformer is design at 500 kV rating voltage and 250 kHz resonant frequency. By coupling air axle and have the air are the electric insulator between primary coil and secondary coil Which primary coil test at 60 degree Group part spark gap is will the Electrostatic gap. This paper propose and consider high voltage high frequency transformer at 500 kV and 250 kHz rated. For use a transformer aforementioned is the equipment for test flash over prenouaena of porcelain insulator and electric insulation.

2553
Analysis of Electric field and Modeling Design of High Voltage Cable terminators for PD Testing Using SF6 Insulator
Analysis of Electric field and Modeling Design of High Voltage Cable terminators for PD Testing Using SF6 Insulator

This paper presents the analysis of electric field by using FEMLAB simulation tool to find the optimal electric field and component designs. Design of Cable terminator is tested by finding PD Value with IEC standard. This paper also proposes the electric stress when we design the cable terminator includes SF6 insulator. The modeling design is very useful for High Voltage engineers to find the optimal solution of Cable terminator design.

2551