จำนวน Repository ( 19 )

การจ่ายโหลดอย่างเหมาะสมในระบบไฟฟ้ากำลัง
การจ่ายโหลดอย่างเหมาะสมในระบบไฟฟ้ากำลัง

This research study is the economic load dispatch ELD is the method of determining the most efficient low-cost and reliable operation of a power system by dispatching the available electricity generation resources to supply the load on the system. The main objective of ELD is to schedule the committed generating units output to meet the required load demand at minimum cost satisfying all unit and system operational constraints. With the proper scheduled outputs of generating units it can lead to a significant cost saving of generating systems. This paper presents an optimization technique to economic load dispatch (ELD) problems with considering the daily load patterns and generator constraints using a particle swarm optimization (PSO). The objective is to minimize the fuel cost. The optimization problem is subject to system constraints consisting of power balance and generation output of each units. The application of a constriction factor into PSO is a useful strategy to ensure convergence of the particle swarm algorithm. The proposed method is able to determine the output power generation for all of the power generation units so that the total constraint cost function is minimized. The performance of the developed methodology is demonstrated by case studies in test system of fifteen-generation units. The results show that the proposed algorithm gives the minimum total cost of generation while satisfying all the constraints and benefiting greatly from saving in power loss reduction.

2563
การต่อลงดินของระบบไฟฟ้าเพื่อลดผลกระทบของแรงดันไฟฟ้าตกชั่วครู่ที่เกิดจากการลัดวงจรแบบหนึ่งเฟสลงดิน
การต่อลงดินของระบบไฟฟ้าเพื่อลดผลกระทบของแรงดันไฟฟ้าตกชั่วครู่ที่เกิดจากการลัดวงจรแบบหนึ่งเฟสลงดิน

The faults in a power distribution system do not only impact to power outage directly. They also cause voltage sag problem spread over the system. A single-line to ground fault is about 70% of the overhead system faults. The magnitude and duration of voltage sag causes the economic damage of the system. This paper presents an analysis of the different systems grounding to mitigate the voltage sag in a power distribution system by using the technical analysis system in case of one phase to ground fault. The objective is to minimize voltage drop for users using the simulation with single line to ground fault in distribution system voltage level at 22 kV PEA’s test system by the computer program. The results show that the grounding method can mitigate the voltage sag and reduce the damage of the economic system.

2562
ชุดทอลองการวิเคราะห์การไหลของไฟฟ้าในระบบไฟฟ้ากำลัง
ชุดทอลองการวิเคราะห์การไหลของไฟฟ้าในระบบไฟฟ้ากำลัง

This thesis presents the design and construction of an experiments of the power flow in the power systems. For the operating system of the power flow in the power systems. Comprise with the real power Reactive power Voltage in the power system. To guide the planning and operation of power systems. The results of the experiment to calculate the pressure at various points in the Power loss of system. As well as finding solutions to problems. Occurring in the system such as under voltage or short circuit in the system. This is the basic of stability analysis of power system operation and planning

2561
Optimal location and size of solar farm on power system using bees algorithm with consideration of solar radiation
Optimal location and size of solar farm on power system using bees algorithm with consideration of solar radiation

A solar energy is most popular renewable energy source which can reduce usage of fuel in thermal generation and impact on environment. The solar energy is a clean and sustainable source. This paper proposed method of finding optimal locating and sizing of PV solar farm on the power system with minimize fuel costs by considering solar radiation in each location of solar farm. The bees algorithm (BA) is used to minimize fuel cost of thermal units by changing location and varying sizes of solar farm with security constraints of power system and solar radiation. IEEE 30 bus test system is used to verify the proposed method. The results show that the proposed method found the optimal position of solar farm with minimum economic cost

2558
Compensation of low frequency oscillation on power system using flexible ac transmission systems devices
Compensation of low frequency oscillation on power system using flexible ac transmission systems devices

This paper presents a study of low-frequency oscillations in compensated electric power systems with Flexible AC Transmission System of the power system frequency using PSAT Tool box To assist in the analysis of the stability of the system When the power transients in power systems is simulated By using standard IEEE 14 bus system as a case study. The Equipment that used to control the swing frequency of the is a flexible electrical power control devices or FACTS are two kinds of serial and parallel. The analysis showed that two models are compared with the time (Time Domain) and see the effect of the Eigen (Eigen Value) of the simulation results show work to see that controls are electrical flexible compensation. of low frequency oscillations in power systems in acceptable coordinates

2558