จำนวน Repository ( 136 )
การสร้างและหาประสิทธิภาพบทเรียนคอมพิวเตอร์ช่วยสอนวิชาการวิเคราะห์ระบบไฟฟ้ากำลัง บทที่ 1-2
The purposes of the research were to create computer assisted instruction for Electric Power System Analysis Chapter 1-2 to find out the efficiency validation of computer assisted instruction based on the standard of 90/90 and to analyse the students learning achievement after using the computer assisted instruction. The subjects in the study were 17 third-year diploma engineering students enrolling at Rajamangala University of Technology Phra Nakhon. The researcher made the experiment by having the students pretest. Then they studied by using the computer assisted instruction focused on practicing basic turning. After the students had studied and had posttest the efficiency of the computer assisted instruction was calculated as well as the learning achievement was analysed. The research result revealed that the efficiency of the computer assisted instruction was at the standard of 90 / 90. Moreover the learning achievement after using the computer assisted instruction was different at the significant level of 0.05.
ความรู้ความเข้าใจและการมีส่วนร่วมในการประหยัดพลังงานไฟฟ้าของนักศึกษาและบุคลากร มหาวิทยาลัยเทคโนโลยีราชมงคลพระนคร
The study of the Knowledge and Participation in Saving Electric Energy of Students and Staffs at Rajamangala University of Technologh Phra Nakhon aimed to find out and compare the level of knowledge and participation in electric energy saving. The population consisted of 865 subjects. The questionairs are desiged for rating five scales check. The reference statistics for data analysis included frequency percentage arithematic mean standard deviation t-test and one way anova respectively.
เครื่องกรองความถี่แบนด์พาสชนิดแอคทีฟที่ปรับตัวได้โดยใช้วงจรแทคโคมิเตอร์
This thesis presented the design and construction of an adaptive active band-pass filter by using a tachometer circuit. The main part was the multi voltage-mode filter circuit based on an operational transconductance amplifier which could automatically adjust the center frequency to adapt to the input signal frequency by the tachometer circuit. The frequency error value in the center frequency was set to be ≤ 3% of the input signal. Furthermore the proposed filter could support the input signal in the frequency range of 10 Hz - 10 kHz. From the simulation and experimental results of the proposed prototype filter it could respond to the frequency according to the theory of the band-pass filter and the error in choosing the center frequency which was 1.45 % and 2.6 % respectively (below the set error value of 3 %). Therefore the proposed filter could be used for real application. The working principles of the proposed prototype filter could also be applied to the noise attenuation circuit of an electrocardiogram machine. Moreover this research could be used as a guideline study for those who want to develop other types of adaptive active filters for higher efficiency.
การวิเคราะห์เซอร์กิตเบรกเกอร์115 kV สำหรับการวางแผนซ่อมบำรุง
HV power distribution system circuit breaker are important devices in substations. Such as Malfunction or deterioration of equipment with in the substation will directing impact on the stability of the power distribution system and affect the reliability of the system. In addition this means that it is necessary to assess the actual condition of the proper condition-based operation and maintenance. Thus this thesis presents condition assessment procedure for equipment by using technical information visual inspection by Weighted Scoring Method. Weighting technique is used to determine important weight testing methods of devices by using Analytic Hierarchy Process (AHP). Testing methods for circuit breaker are such as visual inspection contact timing test. Scoring technique is divided into 1-3 levels by classifying on actual evaluate equipment consisting of consisting of good moderate bad. This thesis proposes a software development in order to organize the database and calculate the analysis of the condition of equipment in 5 HV substations. The evaluation results will be divided into 3 levels good medium and bad condition. According to the evaluation level the maintenance types are separated into 1) regular maintenance 2) increase the frequency of maintenance and monitoring of the test 3) equipment must be improved urgently. Finally abnormal incidents of equipment and cost of HV equipment maintenance can be reduced in effective way.
จักรยานออกกำลังกายผลิตไฟแบบ ON-GRID
This Project presents electric bicycle. The structural feature is the use of the bicycle to be modified as it is designed to spin the rotor of the 5-phase magnetic line generator set and test the voltage distribution. The principle of operation of electric bicycles relies on the mechanical energy gained from cycling. The rotor consists of a series of permanent magnetic poles intersecting with a stator consisting of a set of conductor coils generating an AC voltage and converting it from AC to DC through a diode bridge to obtain DC voltage. To be connected to the boost converter to increase the output side pressure level to get the right voltage to charge a 12 volt battery. batteries. The test has been tested for cycling to generate electricity at a speed of 400 rpm while no-load has a voltage of 23.3 volt and with a load per load and at a speed of 400 rpm the voltage is 12.1 volt If the bicycle is cycled at an increased speed the voltage and current will increase. In order to transmit electric power to the single-phase power system an inverter is used to connect the single-phase power system to transmit to the single-phase power grid.