Design and Construction of High Voltage Diode 100 kV
Design and Construction of High Voltage Diode 100 kV

Diode high voltage the equipment assembles. That have necessity and important for a room practices for test experiment research and for the instruction. But diode high voltage to bring an element in a room practices something still must buy from the foreign countries and expensive. This problem corrects by designing and establish by oneself. This project has designed and build to diode high voltage for a laboratory by diode high voltage 100 kV. That can bring assemble all circuit get the circuit voltage multiplier etc. Building from the inventory at can seek can buy in house diode high voltage. That design and build that is the series diode on print circuit and electric oil insulator. Base principle of diode data technical of the components for applies in designing. The way builds to diode high voltage diagnose of designing builds consider the test diode high voltage the office designs. Which test has followed the objective is pass the power frequency withstand voltage test 120 kV 22 mA

2553
The Electrical Voltage Setting 0-220 Volts by Software
The Electrical Voltage Setting 0-220 Volts by Software

This project is the study about making the electrical voltage setting 0 – 220 Volts by software system with electrical voltage control of the auto transformer while it has 100 kv 10 kVA Especially the electrical voltage control has 65 ampares 0-220 volt 1 phase 50 Hz By the application of Visual Basic version 6 to the software and then use the micro controller in the board to control the stepper motor by setting the core of the auto transformer in the set of pattern while a computer is setting far away from the electrical High Voltage control and then it will apply the measurement system to the monitor display of software process system for development of software to the electrical Voltage section in the Electrical High voltage Lab to safety the danger of the test.

2553
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz

This project design and constructions high voltage high frequency transformer or tesla transformer. The tesla transformer is design at 500 kV rating voltage and 250 kHz resonant frequency. By coupling air axle and have the air are the electric insulator between primary coil and secondary coil Which primary coil test at 60 degree Group part spark gap is will the Electrostatic gap. This paper propose and consider high voltage high frequency transformer at 500 kV and 250 kHz rated. For use a transformer aforementioned is the equipment for test flash over prenouaena of porcelain insulator and electric insulation.

2553
A Study of Appropriate Model of Unit Cost for Electricity Generation in Thailand
A Study of Appropriate Model of Unit Cost for Electricity Generation in Thailand

Today Thailand has been facing the energy problems due to the limited sources of natural energy. Meanwhile the power consumption has been growing constantly and the tendency of consumption increases each year. Therefore to solve these energy problems especially in electricity-generating power which have been demanded throughout the country the National Economic and Social Advisory Council had a resolution to submit the Cabinet the comments on nuclear-electricity generation and proposed the government for approval on August 24 2003. The government assigned the National Energy Commission’s policy to set out the electricity production plan by nuclear power plant requiring that the power house during 2020-2021 will be established. The Electricity Generation Authority of Thailand (EGAT) has executed “the Power Development Plan 2007” established the many sets of committees to accommodate the plan and carried out surveying for dominant information for examples parameters and variables issues of resulting effect and economic expansion so that these would be summarized and submitted to the government under the production plan procedure set out by EGAT. According to the production plan for future energy reserves the new power houses have been established. To accommodate the economic expansion some potential factors needed to be taken into consideration included fuel supplied and low cost. Previous researches demonstrated that nuclear power plant was lowest on cost. In present study the appropriate model of unit cost for electricity generation in Thailand was examined. The equation was described below;....

2553
Design and Product Development Ceramics Using for Making Wall of Energy Conservation Building
Design and Product Development Ceramics Using for Making Wall of Energy Conservation Building

This research aims to study and develop ceramics material using in the wall construction which can be used to proof the heat and water reduce absorbed humidity in the building. The product can save the energy especially the building which is set the air conditioning. The experiment found that the proportion of clay body can be developed and the result of thermal conductivity (K- value) was 0.111 W/ m. /K the permeability was 7 percent the glaze can be used to proof water. The product was compared to three kinds of construction materials which are brick concrete masonry unit and autoclaved aerated concrete found that K- value and permeability were lower. Moreover it can proof water and save more energy for the air conditioning building.

2553