จำนวน Repository ( 21 )
การสร้างและหาประสิทธิภาพบทเรียนคอมพิวเตอร์ช่วยสอนวิชาการวิเคราะห์ระบบไฟฟ้ากำลัง บทที่ 1-2
The purposes of the research were to create computer assisted instruction for Electric Power System Analysis Chapter 1-2 to find out the efficiency validation of computer assisted instruction based on the standard of 90/90 and to analyse the students learning achievement after using the computer assisted instruction. The subjects in the study were 17 third-year diploma engineering students enrolling at Rajamangala University of Technology Phra Nakhon. The researcher made the experiment by having the students pretest. Then they studied by using the computer assisted instruction focused on practicing basic turning. After the students had studied and had posttest the efficiency of the computer assisted instruction was calculated as well as the learning achievement was analysed. The research result revealed that the efficiency of the computer assisted instruction was at the standard of 90 / 90. Moreover the learning achievement after using the computer assisted instruction was different at the significant level of 0.05.
การปรับปรุงคุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าโดยการเชื่อมต่อแหล่งผลิตไฟฟ้าแบบกระจายตัวพลังงานแสงอาทิตย์
This thesis presents improving power quality in power distribution system with integration of photovoltaic energy distributed generation having objectives to improve power quality in distribution system model of voltage sag and voltage swell in distribution system model of power loss in distribution system application of mathematical model model of power generation by using solar energy and distributed generation connection technique simulation. In this thesis the power flow was tested with Newton-Raphson algorithm joining with mathematical model. The case study was done by reduction of power loss in distribution system by using techniques of connection of distributed generation joining with model of distribution system 33 bus. The case study about improvement of voltage sag and voltage swell in distribution system used connection techniques of distributed generation joining with model of distribution system 69 bus. The study found that technique of connection of distributed generation that was presented could reduce power loss and showed the percentage of improvement of voltage sag and voltage swell in distribution system especially voltage sag case according to IEEE 1159-1995 standard. This thesis showed that severity level of voltage sag depended on the size and duration of each distribution system model situation by photovoltaic energy distributed generation can reduce voltage sag.
การประยุกต์การใช้พลังงานแบบผสมผสานเพื่อบูรณาการกับภาคการเกษตรกรรม
The application of integrated energy use in the agriculture sector It is presented in the form of using renewable energy from solar energy to produce electricity to use in conjunction with other sources of electricity such as generators or electric power systems. Using solar panels or solar cells the size and number of panels does not exceed 300 watts 4 panels and the electrical system of the electrical system. Supply electric power to the water pump size does not exceed the rating of 1500 watts 220 volts. Solar power supply systems alone may be affected by weather conditions or electrical power supplies. Including the quality of electricity obtained from solar energy and will result in the water pump not working efficiently. Therefore the application of solar energy by using a power supply system from 2 sources by using a hybrid inverter device to select the power supply from the solar cell is the main power and the power supply from the memory system is the backup power. Therefore a research project on the application of solar water pumps in a mixed system for agriculture is proposed to increase the efficiency of electric power distribution. This application of solar water pump hybrid system for agriculture when used with water pumps can normally help to save electricity and can also use solar energy instead of using electricity to pump water. Let the water pump and can work efficiently.
การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า
This thesis presents the combined loss reduction approach to apply in distribution system. The thesis objective reduces the loss in the distribution system when all voltage magnitude levels at connection points must under the limits. Therefore the Simulated Annealing Technical selects as searching tool to find the suitable location of DG and Capacitor. The propose technique applies to the distribution system 69 buses model. The results shown that this technique can reduce in power losses from properly organize the location of DG and Capacitor. Moreover it can also balance and increase the voltage levels. The propose Simulated Annealing Technical is used to determine and organize the sectionalizing and tie switches in the feeder which installs DG and Capacitor by considering the power losses and the number of time to change the status of disconnecting switches.
การปรับปรุงตัวประกอบกาลังด้วยวิธีการควบคุมกาลังไฟฟ้ารีแอคทีฟ
To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor the higher the value it is necessary to buildings offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate. This paper presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4 fifth 5 and sixth 6 precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences. As a result when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 164-watt making the current decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.82.2 flow down from 2.360 rest 0.942 amps of power factor value up from 0.308 to 1.0.