จำนวน Repository ( 15 )
การปรับปรุงตัวประกอบกาลังด้วยวิธีการควบคุมกาลังไฟฟ้ารีแอคทีฟ
To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor the higher the value it is necessary to buildings offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate. This paper presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4 fifth 5 and sixth 6 precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences. As a result when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 164-watt making the current decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.82.2 flow down from 2.360 rest 0.942 amps of power factor value up from 0.308 to 1.0.
เทคนิคการจัดเรียงสายป้อนและการกำหนดตำแหน่งตัวเก็บประจุในระบบจำหน่ายไฟฟ้าเพื่อทำให้ค่าดัชนีโหลดสมดุลต่ำสุด
This paper presents an efficient algorithm for optimization of radial distribution systems by a feeder reconfiguration to balance feeder loads and eliminate overload conditions. The system load-balancing index is used to determine the loading conditions of the system and maximum system loading capacity. The index value has to be minimum in the optimal feeder reconfiguration of load balancing. A method based on Tabu search algorithm The Tabu search algorithm is employed to search for the optimal feeder reconfiguration. Simulation results for a radial 69-bus system with reconfiguration and capacitors placement. The study results show that the distribution system with capacitor placement and optimal on/off patterns of the switches feeders reconfiguration can be load balancing in distribution systems.
แบบจำลองอุปกรณ์ป้องกันในระบบสายส่งสามเฟส
This project report proposes a design and construction of model of protection equipment for three-phase transmission line by voltage relay for protect. By protection equipment can protect the transmission line from over voltage and under voltage on the transmission line The objective of design and construction model of protection equipment for three-phase transmission line. The objective for construction model of protection equipment for three-phase transmission line. For understand power system protection principles. And understand using to protection equipment for three-phase transmission line correct. From experimentation model of protection equipment could protect over voltage and under voltage on the transmission line
Optimal location and size of solar farm on power system using bees algorithm with consideration of solar radiation
A solar energy is most popular renewable energy source which can reduce usage of fuel in thermal generation and impact on environment. The solar energy is a clean and sustainable source. This paper proposed method of finding optimal locating and sizing of PV solar farm on the power system with minimize fuel costs by considering solar radiation in each location of solar farm. The bees algorithm (BA) is used to minimize fuel cost of thermal units by changing location and varying sizes of solar farm with security constraints of power system and solar radiation. IEEE 30 bus test system is used to verify the proposed method. The results show that the proposed method found the optimal position of solar farm with minimum economic cost
Creating and evaluating the effectiveness of computer assisted instruction program subject electric power system analysis chapter 3-6.
The purposes of the research were to create and efficiency validation of computer assisted for the courses of practiced to reading. Creating and Evaluating the Effectiveness of Computer Assisted Instruction Program Subject Electric Power System Analysis Chapter 3-6 based standard and analyses the leaning achievement of the student after by using computer assisted instruction. The subjects in the study were first year diploma students enrolled in Rajamangala University of Technology Phra Nakhon . The Researcher using the experiment by let the students do until test before class And then study by using computer assisted instruction focused on practiced to basic turning. After that let students do the unit test again at the class and calculate to find out the efficiency of the computer assisted instruction and analyses the leaning achievement of students after study . The research result revealed that the efficiency of the computer assisted Instruction was efficient in standard Moreover after learning achievement At significant level of 0.05 .