จำนวน Repository ( 19 )

Comparison of load-frequency control of interconnected power system with fuzzy logic and artificial neural Network controller
Comparison of load-frequency control of interconnected power system with fuzzy logic and artificial neural Network controller

This paper is a presentation of the Load-Frequency Control (LFC) of Interconnected Power System by using Fuzzy Logic and Artificial Neural Network (ANN) Controller. The both of controller have been widely applied for handling the system control of Industries and Engineering. Since the Load-Frequency behaviors of power system of uncontrolled and PI- Controller or Fuzzy Logic Controller (FLC) wanted to the stability at first of energize and load in a short time. The control system and controller then be significant for to go forward reform stability of interconnected energize power system a short time. In this research we have the Load-Frequency Controller of Interconnected Power System by using Artificial Neural Network Controller the improved can compared with conventional Fuzzy Logic Controller at power total 47.55 MW and load changing of power plan No.3 is 0.02 p.u. (1.75 MW)

2558
Creating and evaluating the effectiveness of computer assisted instruction program subject electric power system analysis chapter 3-6.
Creating and evaluating the effectiveness of computer assisted instruction program subject electric power system analysis chapter 3-6.

The purposes of the research were to create and efficiency validation of computer assisted for the courses of practiced to reading. Creating and Evaluating the Effectiveness of Computer Assisted Instruction Program Subject Electric Power System Analysis Chapter 3-6 based standard and analyses the leaning achievement of the student after by using computer assisted instruction. The subjects in the study were first year diploma students enrolled in Rajamangala University of Technology Phra Nakhon . The Researcher using the experiment by let the students do until test before class And then study by using computer assisted instruction focused on practiced to basic turning. After that let students do the unit test again at the class and calculate to find out the efficiency of the computer assisted instruction and analyses the leaning achievement of students after study . The research result revealed that the efficiency of the computer assisted Instruction was efficient in standard Moreover after learning achievement At significant level of 0.05 .

2554
การสร้างและหาประสิทธิภาพบทเรียนคอมพิวเตอร์ช่วยสอนวิชาการวิเคราะห์ระบบไฟฟ้ากำลัง บทที่ 1-2
การสร้างและหาประสิทธิภาพบทเรียนคอมพิวเตอร์ช่วยสอนวิชาการวิเคราะห์ระบบไฟฟ้ากำลัง บทที่ 1-2

The purposes of the research were to create computer assisted instruction for Electric Power System Analysis Chapter 1-2 to find out the efficiency validation of computer assisted instruction based on the standard of 90/90 and to analyse the students learning achievement after using the computer assisted instruction. The subjects in the study were 17 third-year diploma engineering students enrolling at Rajamangala University of Technology Phra Nakhon. The researcher made the experiment by having the students pretest. Then they studied by using the computer assisted instruction focused on practicing basic turning. After the students had studied and had posttest the efficiency of the computer assisted instruction was calculated as well as the learning achievement was analysed. The research result revealed that the efficiency of the computer assisted instruction was at the standard of 90 / 90. Moreover the learning achievement after using the computer assisted instruction was different at the significant level of 0.05.

2553
การปรับปรุงคุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าโดยการเชื่อมต่อแหล่งผลิตไฟฟ้าแบบกระจายตัวพลังงานแสงอาทิตย์
การปรับปรุงคุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าโดยการเชื่อมต่อแหล่งผลิตไฟฟ้าแบบกระจายตัวพลังงานแสงอาทิตย์

This thesis presents improving power quality in power distribution system with integration of photovoltaic energy distributed generation having objectives to improve power quality in distribution system model of voltage sag and voltage swell in distribution system model of power loss in distribution system application of mathematical model model of power generation by using solar energy and distributed generation connection technique simulation. In this thesis the power flow was tested with Newton-Raphson algorithm joining with mathematical model. The case study was done by reduction of power loss in distribution system by using techniques of connection of distributed generation joining with model of distribution system 33 bus. The case study about improvement of voltage sag and voltage swell in distribution system used connection techniques of distributed generation joining with model of distribution system 69 bus. The study found that technique of connection of distributed generation that was presented could reduce power loss and showed the percentage of improvement of voltage sag and voltage swell in distribution system especially voltage sag case according to IEEE 1159-1995 standard. This thesis showed that severity level of voltage sag depended on the size and duration of each distribution system model situation by photovoltaic energy distributed generation can reduce voltage sag.

2566
การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า
การผสานแนวทางการลดกำลังสูญเสียเพื่อประยุกต์ใช้ในระบบจำหน่ายไฟฟ้า

This thesis presents the combined loss reduction approach to apply in distribution system. The thesis objective reduces the loss in the distribution system when all voltage magnitude levels at connection points must under the limits. Therefore the Simulated Annealing Technical selects as searching tool to find the suitable location of DG and Capacitor. The propose technique applies to the distribution system 69 buses model. The results shown that this technique can reduce in power losses from properly organize the location of DG and Capacitor. Moreover it can also balance and increase the voltage levels. The propose Simulated Annealing Technical is used to determine and organize the sectionalizing and tie switches in the feeder which installs DG and Capacitor by considering the power losses and the number of time to change the status of disconnecting switches.

2564