การวิเคราะห์แรงดันตกชั่วขณะเมื่อมีการติดตั้งแหล่งผลิตไฟฟ้าแบบกระจายตัวในระบบจำหน่าย
This research presents an Analysis of Voltage Sags on the Installation of Distributed Generation in the Distribution System. The computer program PSCAD/EMTDC (Power Systems Computer Aided Design / Electromagnetic Transient in DC system) version 4.2 is applied to provide electrical parameters for the modeling and simulation and to analyze the fault occurred which resulted in voltage sag. Test results from PSCAD/EMTDC show the values of voltage sag when 5 types of fault are occurred (Single Line to Ground Fault Double Line to Ground Fault Three Phase to Ground Fault Line to Line Fault and Three Phase Fault). For all cases the value of root mean square voltage before fault is 100% or 1.0 pu. It can be seen that for both radial line and closed circuit when DG are installed in the system the value of phase to ground RMS residual voltage and phase to phase RMS residual voltage at the bus of Bang-pa-in 2 substation are more than the values in case of the system without DG.
การลดผลกระทบจากฟ้าผ่าในระบบจำหน่ายไฟฟ้า
Most of Metropolitan Electricity Authority (MEA) electric power system is using overhead line. It is 94% in the system including subtransmission distribution and low voltage system. All of them were installed on concrete pole. At present many public facilities have been built such as Sky-Train. It causes more constrains for construction with concrete pole due to lack of right of way. MEA needs to using electrical monopole plays an important role. It’s easier than concrete pole for construction and it requires less construction area than concrete pole. This research evaluation of The Reduce Effect of Lightning on Transmission Line. Case lightning strike on overhead ground wire (OHGW) at pole top of electrical monopole with suspension insulator Focusing on three factors is pole top voltage critical current and back flashover rate (BFOR). ATP-EMTP software is used for simulation. The results show that BFOR is reduced by 79% on electrical monopole structure with suspension insulator compared with existing concrete pole. BFOR is also reduced by 33.17% on concrete pole with external ground wire. The results could be served as a guideline in subtransmission line design and improvement in MEA power system.
การติดตั้งแหล่งผลิตไฟฟ้าแบบกระจายตัวเพื่อเพิ่มความเชื่อถือได้ในระบบจำหน่ายไฟฟ้า
This paper presents reliability evaluation in distribution system with distributed generation. The main objective is to minimize the customer interruption cost subject to given number of distributed generation. The minimization problem for customer interruption cost in solved by the developed tabu search algorithm together with reliability worth analysis that provide an indirect measure for cost implication associated with power outages. The developed methodology is tested with a distribution system of Roy Billinton Test System (RBTS) bus 2 consist of 15 buses and 22 load points. Numerical results from the tests demonstrate that the optimal distributed generation placement can be used to promote reliability of the distribution systems.
การประเมินคุณภาพไฟฟ้าในระบบจำหน่ายที่จ่ายไฟให้พื้นที่นิคมอุตสาหกรรม
This paper presents an assessment of the quality of electricity transmission and distribution system to supply power to the industrial area. The objective is to analyze the power quality that customer in the industrial area need high level. By analyzing the power quality of Provincial Electricity Authority (PEA) in transmission system 115 kV distribution system 22 kV and 400/230 volt in Rojana industrial park from power quality meters. The study concluded that the phenomenon occurs continuously consist of RMS voltage power frequency voltage unbalance short term flicker long term flicker Harmonic meet the standards applied to all. The phenomenon occurs temporary consist of transient voltage dip voltage swell interruption in the conclusion the power quality problems caused by voltage dip most especially with loads which are sensitive to voltage. From the moment the measurement showed that the voltage dip on transmission system 115 kV maximum of 19 times. The voltage dip that occur including three voltage level of 30 times there are events that do not pass SEMI F47 standard 12 times or 40%.
การศึกษาผลกระทบทางเศรษฐศาสตร์สำหรับระบบจำหน่ายไฟฟ้าที่มีเครื่องกำเนิดไฟฟ้าแบบกระจายตัว
A distributed generation is a small-scale Installed in the customer density sources. The benefits of distributed energy resources is one example. To improve the reliability of power distribution system for the better. The increased reliability of power distribution system that is connected to the source of power distribution efficiency depends on the size of the supply and installation of power distribution are considered appropriate. To Evaluation the reliability in distribution system with the main purpose is to the minimization for customer interruption cost. The technique employed to minimization problem for customer interruption cost in solved by the developed tabu search algorithm together with reliability worth analysis that provide an indirect measure for cost implication associated with power failure. The developed methodology is tested with a distribution system of Roy Billinton Test System (RBTS) bus 2. Numerical results from the tests demonstrate that distributed generation can be used to promote economy and reliability of the distribution systems.