จำนวน Repository ( 19 )

การปรับปรุงตัวประกอบกาลังด้วยวิธีการควบคุมกาลังไฟฟ้ารีแอคทีฟ
การปรับปรุงตัวประกอบกาลังด้วยวิธีการควบคุมกาลังไฟฟ้ารีแอคทีฟ

To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor the higher the value it is necessary to buildings offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate. This paper presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4 fifth 5 and sixth 6 precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences. As a result when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 164-watt making the current decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.82.2 flow down from 2.360 rest 0.942 amps of power factor value up from 0.308 to 1.0.

2563
เทคนิคการจัดเรียงสายป้อนและการกำหนดตำแหน่งตัวเก็บประจุในระบบจำหน่ายไฟฟ้าเพื่อทำให้ค่าดัชนีโหลดสมดุลต่ำสุด
เทคนิคการจัดเรียงสายป้อนและการกำหนดตำแหน่งตัวเก็บประจุในระบบจำหน่ายไฟฟ้าเพื่อทำให้ค่าดัชนีโหลดสมดุลต่ำสุด

This paper presents an efficient algorithm for optimization of radial distribution systems by a feeder reconfiguration to balance feeder loads and eliminate overload conditions. The system load-balancing index is used to determine the loading conditions of the system and maximum system loading capacity. The index value has to be minimum in the optimal feeder reconfiguration of load balancing. A method based on Tabu search algorithm The Tabu search algorithm is employed to search for the optimal feeder reconfiguration. Simulation results for a radial 69-bus system with reconfiguration and capacitors placement. The study results show that the distribution system with capacitor placement and optimal on/off patterns of the switches feeders reconfiguration can be load balancing in distribution systems.

2561
แบบจำลองอุปกรณ์ป้องกันในระบบสายส่งสามเฟส
แบบจำลองอุปกรณ์ป้องกันในระบบสายส่งสามเฟส

This project report proposes a design and construction of model of protection equipment for three-phase transmission line by voltage relay for protect. By protection equipment can protect the transmission line from over voltage and under voltage on the transmission line The objective of design and construction model of protection equipment for three-phase transmission line. The objective for construction model of protection equipment for three-phase transmission line. For understand power system protection principles. And understand using to protection equipment for three-phase transmission line correct. From experimentation model of protection equipment could protect over voltage and under voltage on the transmission line

2561
ระบบควบคุมการจัดเก็บพลังงานไฟฟ้าจากเซลล์แสงอาทิตย์โดยใช้ตัวเก็บประจุไฟฟ้าแบบซุปเปอร์ควบคุมด้วยระบบฝังตัว
ระบบควบคุมการจัดเก็บพลังงานไฟฟ้าจากเซลล์แสงอาทิตย์โดยใช้ตัวเก็บประจุไฟฟ้าแบบซุปเปอร์ควบคุมด้วยระบบฝังตัว

To store electrical power from solar cells are generally used battery as storage. Recent development in capacitor technology achieves with higher capacitancc smaller and low cost especially dcvelopment of a supcr capacitor (doublc laycrs). This research study used a super capacitor to store electrical power from solar cells. The results show that super and electrolyte capacitor can be used without battery with more power density and fast charge. But capacitor discharging must be controlled. The important disadvantage is super capacitor is used with low voltage and high rate of charge leakage. In case of electrolytic capacitor can use with higher voltage low rate of charge leakage but lower capacitance.

2555