จำนวน Repository ( 277 )

Design and Product Development Ceramics Using for Making Wall of Energy Conservation Building
Design and Product Development Ceramics Using for Making Wall of Energy Conservation Building

This research aims to study and develop ceramics material using in the wall construction which can be used to proof the heat and water reduce absorbed humidity in the building. The product can save the energy especially the building which is set the air conditioning. The experiment found that the proportion of clay body can be developed and the result of thermal conductivity (K- value) was 0.111 W/ m. /K the permeability was 7 percent the glaze can be used to proof water. The product was compared to three kinds of construction materials which are brick concrete masonry unit and autoclaved aerated concrete found that K- value and permeability were lower. Moreover it can proof water and save more energy for the air conditioning building.

2553
Influence of Electrode Force Affecting the Complete of the Resistance Spot Welding
Influence of Electrode Force Affecting the Complete of the Resistance Spot Welding

This research was to influence of electrode force affecting the complete of the resistance spot welding. The specimen was mild steel sheet metal has 1 mm. thickness. Then applied the force to the specimen are 1.0 2.0 3.0 4.0 and 5.0 kN. The welded specimens were tested by tensile shear testing according to JIS Z 3136: 1999 and Macro structure testing according to JIS Z 3139: 1978.The results showed that electrode force had affected on tensile shear and nugget size at 95% confidential (P value > 0.05). The low electrode force had increase the nugget heating because it had a high resistance (Q=I2Rt) and increase the gab between specimen. When the resistance increasing so the current flow will difficult to passed that fusion zone will had a high heating. It will affected to nugget seize heat affected zone and mechanical properties decreasing. The electrode forces are complete 2.0 kN. Tensile shear 6.39 kN and Nugget Size 5.83 mm. This data can be applied to be used as process monitoring of resistance spot weld quality.

2553
Analysis of Electric field and Modeling Design of High Voltage Cable terminators for PD Testing Using SF6 Insulator
Analysis of Electric field and Modeling Design of High Voltage Cable terminators for PD Testing Using SF6 Insulator

This paper presents the analysis of electric field by using FEMLAB simulation tool to find the optimal electric field and component designs. Design of Cable terminator is tested by finding PD Value with IEC standard. This paper also proposes the electric stress when we design the cable terminator includes SF6 insulator. The modeling design is very useful for High Voltage engineers to find the optimal solution of Cable terminator design.

2551
A Microstrip Folded Resonator Sensor for Measurement of Dielectric Constant
A Microstrip Folded Resonator Sensor for Measurement of Dielectric Constant

A microstrip folded ring resonator sensor for measurement of dielectric constant in a compact area of material under test is proposed. The resonant characteristics of resonator vary with dielectric constant of material. Limitations in the microwave frequency response performances of the proposed sensor have been carefully studied in a range from 500 MHz to 3 GHz. It has been found that the proposed sensor has great potentials for practical applications in view of low cost and monolithic integration capability with a driving circuit.

2551
The Analysis of high-Voltage Electric Field Stress in Lp and Ls coils of Tesla Transformer for studying the efficiency design
The Analysis of high-Voltage Electric Field Stress in Lp and Ls coils of Tesla Transformer for studying the efficiency design

This article presents The Analysis for high-Voltage Electric Stress in Lp and Ls coils of Tesla Transformer for studying the efficiency design. The tesla transformer is designed at 350kV rating Voltage and 120 kHz resonant frequency. The effect of high voltage when we designed the coil has impact to Electric Stress between primary and secondary coil because the tesla transformer uses air core. The insulator of coil also has problem on the reason as flashover on the 2 coils. The best dimension among coil has to present in this paper by using optimal mathematical solution. The simulation results show performance of the solution and ensure the methodology with positive way.

2551