จำนวน Repository ( 35 )

Fluctuation Voltage Control of Wind Turbines via STATCOM
Fluctuation Voltage Control of Wind Turbines via STATCOM

This paper presents distributed STATCOM for controlling voltage in distribution line with wind turbines generations at 48 volts. The connection of wind turbine to distribution systems may affect the voltage quality offered to the consumers. One of the factors contributing to this effect is the rapid variations of the wind turbine output power which cause respective fluctuations in the supply voltage. This paper presents the design control and analysis of a Distributed STATCOM when combined with a wind turbine comprising small variable speed generators in this paper it is shown that the distributed STATCOM controlled via a rotating referent frame: RRF and recursive DFT are simple method to DSP control technique. The result of experiments the STATCOM can improve the transient stability voltage of wind turbine that we have referred the IEEE1159:1995 standard of power quality.

2553
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz
Design and Construction High Voltage,High Frequency Transformer Rated 500 kV 250 kHz

This project design and constructions high voltage high frequency transformer or tesla transformer. The tesla transformer is design at 500 kV rating voltage and 250 kHz resonant frequency. By coupling air axle and have the air are the electric insulator between primary coil and secondary coil Which primary coil test at 60 degree Group part spark gap is will the Electrostatic gap. This paper propose and consider high voltage high frequency transformer at 500 kV and 250 kHz rated. For use a transformer aforementioned is the equipment for test flash over prenouaena of porcelain insulator and electric insulation.

2553
Analysis and control of Shunt-Compensator for mitigating Unbalanced Voltages
Analysis and control of Shunt-Compensator for mitigating Unbalanced Voltages

This paper presents the analysis and the control of shunt-compensator for improving unbalanced voltages of power distribution systems in Thailand. The shunt-compensator is connected to the low voltage level in power distribution system. The analysis detail and the design of shunt-compensator obtain by using the voltage vector control (mathematical model with the stationary reference frame and synchronous reference frames). The unbalanced voltages are identified by using positive and negative sequence detection that can be shown in the synchronous reference frame. This method also presents the decoupling control including feed-forward control to compensate both positive and negative sequence component of grid voltage. The power circuit of the shunt-compensator and the distribution network are modeled by Provincial Electricity Authority (PEA) of Thailand that is the same as worldwide standard of power distribution system. By using computer program the simulation results showed the benefit and the performance of proposed methodology which obviously ensure the performance of shunt-compensator for mitigating the unbalanced voltages.

2551
Analysis of Electric field and Modeling Design of High Voltage Cable terminators for PD Testing Using SF6 Insulator
Analysis of Electric field and Modeling Design of High Voltage Cable terminators for PD Testing Using SF6 Insulator

This paper presents the analysis of electric field by using FEMLAB simulation tool to find the optimal electric field and component designs. Design of Cable terminator is tested by finding PD Value with IEC standard. This paper also proposes the electric stress when we design the cable terminator includes SF6 insulator. The modeling design is very useful for High Voltage engineers to find the optimal solution of Cable terminator design.

2551
The Analysis of high-Voltage Electric Field Stress in Lp and Ls coils of Tesla Transformer for studying the efficiency design
The Analysis of high-Voltage Electric Field Stress in Lp and Ls coils of Tesla Transformer for studying the efficiency design

This article presents The Analysis for high-Voltage Electric Stress in Lp and Ls coils of Tesla Transformer for studying the efficiency design. The tesla transformer is designed at 350kV rating Voltage and 120 kHz resonant frequency. The effect of high voltage when we designed the coil has impact to Electric Stress between primary and secondary coil because the tesla transformer uses air core. The insulator of coil also has problem on the reason as flashover on the 2 coils. The best dimension among coil has to present in this paper by using optimal mathematical solution. The simulation results show performance of the solution and ensure the methodology with positive way.

2551