จำนวน Repository ( 6 )
การควบคุมความถี่ -โหลด ของการเชื่อมต่อระบบการผลิตไฟฟ้าจากโซล่าร์ฟาร์มและกังหันลม
The effects of load frequency control (LFC) of interconnected distribution power system in tie-line substation area load –frequency stability and the frequency respond at distribution generator (DG) are very important for interconnected control power system of tie-line area. The generating power system of solar farm and wind turbine which have interconnected distribution power system in tie-line substation area were tested using 3 simulation parameters: non-controller Automatic Voltage Regulator (AVR) and with Pl Controller. The results showed that there were 3 types of load and frequency changing in the interconnected area: load changed 0.02 p.u. had frequency of load changed 0.025 Hz and large disturbance. Comparisons of load-frequency to respond for steady state the time respond was 7.9 seconds for non-controller 5.4 seconds for AVR and 1.7 seconds for under controlled system at 0.1 p.u using Pl controller. Therefore the Pl controller has better efficiency than non-controller about 31 % and AVR about 16%. It can be concluded that the interconnected distribution power system in tie-line substation area controlling for storage for connected grid had better efficiency and optimization of generating power from renewable solar farm and wind turbine which have interconnected distribution power system in the nearby are balance of controlling of the original system.
การจำลองกังหันลมเชื่อมต่อระบบกริดไฟฟ้า 1 เฟส
This research project presents about wind turbine simulation for connected single phase grid system using hysteresis current control technique to generate PWM signals for controlling a single-phase voltage source inverter. The simulation system presented here uses the program. MATLAB/Simulink in the simulation of the wind turbine connected to the shaft of a three-phase permanent magnet generator is produced by alternating current through the full bridge rectifier circuit. Then the power supply is applied to the single-phase inverter circuit which is connected to the single-phase autotransformer to power transfer to the single-phase grid system. The simulation results confirm the validity of the proposed system with satisfaction under various conditions.
การวิเคราะห์ศักยภาพพลังงานลมและข้อมูลลมรายปีบริเวณพื้นที่ อำเภอสะเมิง จังหวัดเชียงใหม่
In this study the wind speed characteristic and evaluation of wind power generation at Samoeng district Chiang Mai were investigated using wind speed data and wind direction data during time of January 2011 to December 2011 and measured at a height of 20 40 and 80 m above ground level. It was found that the mean wind speed of 3.8 3.92 and 4.30 m/s. While the mean wind direction of 20.73% and indicating from the southwest. The mean of power density of 107 W/m2 the shape parameter (k) was 1.715 1.633 and 1.783 scale parameter (c) of 3.649 3.651 and 4.092 m/s the mean of wind shear coefficient was 0.19. The evaluation of wind energy for electricity generation by install the wind turbine of Nordex N50 from Germany and Vestas V90 from Denmark were capacity of 800 kW and 3 MW. It could produce annual electricity of 1761379 kWh and 3772400 kWh and the capacity factor show 25.13% and 14.35% respectively. Finally the results showed the northern area of Thailand was suitable for wind power development in further.
การวิเคราะห์คุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าที่มีแหล่งผลิตไฟฟ้าพลังงานลม
This Thesis presents an analysis of wind turbines in a power distribution system that has a wind power source. By comparing the wind turbine with 3 blades and 4 wind turbines while there is no distribution in the distribution system. And the load is distributed in the distribution system To analyze the differences of these 2 wind turbines analyze the pressure values The power quality in the distribution system that occurs. And able to apply wind turbine energy for sustainability And practices to support the correct power supply In the distribution system and able to provide electricity with efficiency and reliability Wind turbine when connecting to the electricity distribution system There is a significant impact on the power distribution system such as the impact on the power loss. Pressure impact etc. It can be seen that the wind turbine with 3 blades works less than the wind turbine with 4 blades not so much. Therefore the test shows that the analysis of the electricity quality in this distribution system for use as a case study And continue to improve the production of wind turbines in the electricity distribution system.
Wind turbine simulator based on constant Volts/Hertz control three phase induction motor drives
This article presents the application of the constant Volts per Hertz control to control a three phase induction motor has torque and speed characteristics similar to wind turbine. Due to this method is not complicated and does not require the parameters of motor. As a result the accuracy of control is independent of variation of the parameters of motor. Furthermore the equation for compensate the difference between the moment of inertia of wind turbine and motor which is consistent with the mentioned control method is proposed. In order to make the dynamic responses of the wind turbine simulator similar to the wind turbine and to overcome the problems of noise amplification from differentiation that leads to instability of the system. The simulation results in Matlab/Simulink program show that the proposed wind turbine simulator can imitate the wind turbine accurately both in dynamic and steady state conditions