จำนวน Repository ( 16 )
การปรับปรุงคุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าโดยการเชื่อมต่อแหล่งผลิตไฟฟ้าแบบกระจายตัวพลังงานแสงอาทิตย์
This thesis presents improving power quality in power distribution system with integration of photovoltaic energy distributed generation having objectives to improve power quality in distribution system model of voltage sag and voltage swell in distribution system model of power loss in distribution system application of mathematical model model of power generation by using solar energy and distributed generation connection technique simulation. In this thesis the power flow was tested with Newton-Raphson algorithm joining with mathematical model. The case study was done by reduction of power loss in distribution system by using techniques of connection of distributed generation joining with model of distribution system 33 bus. The case study about improvement of voltage sag and voltage swell in distribution system used connection techniques of distributed generation joining with model of distribution system 69 bus. The study found that technique of connection of distributed generation that was presented could reduce power loss and showed the percentage of improvement of voltage sag and voltage swell in distribution system especially voltage sag case according to IEEE 1159-1995 standard. This thesis showed that severity level of voltage sag depended on the size and duration of each distribution system model situation by photovoltaic energy distributed generation can reduce voltage sag.
การแปลงหน้าที่ทางคุณภาพเพื่อพัฒนาผลิตภัณฑ์ผลิตไฟฟ้าจากลมระบายความร้อนของเครื่องปรับอากาศ
This research had the objective to design and develop power production from daily life leftovers for their highest benefit of utilization by using the principle of quality function development and power generator that changed mechanical energy into electric energy. In developing electric generator product from air conditioner condensing unit the researcher found that there were 4 important factors including speed installation distance size and cross-sectional area of the fan and the test was conducted between 8.00-17.00 hours. The researcher collected the data and analyzed the test result and found that the best result in the test was to install the product at the distance of 10 cm by using an 18 fan in order to acquire the best voltage and the data were collected so that they could be implemented in developing such product in the future.
การควบคุมความถี่ -โหลด ของการเชื่อมต่อระบบการผลิตไฟฟ้าจากโซล่าร์ฟาร์มและกังหันลม
The effects of load frequency control (LFC) of interconnected distribution power system in tie-line substation area load –frequency stability and the frequency respond at distribution generator (DG) are very important for interconnected control power system of tie-line area. The generating power system of solar farm and wind turbine which have interconnected distribution power system in tie-line substation area were tested using 3 simulation parameters: non-controller Automatic Voltage Regulator (AVR) and with Pl Controller. The results showed that there were 3 types of load and frequency changing in the interconnected area: load changed 0.02 p.u. had frequency of load changed 0.025 Hz and large disturbance. Comparisons of load-frequency to respond for steady state the time respond was 7.9 seconds for non-controller 5.4 seconds for AVR and 1.7 seconds for under controlled system at 0.1 p.u using Pl controller. Therefore the Pl controller has better efficiency than non-controller about 31 % and AVR about 16%. It can be concluded that the interconnected distribution power system in tie-line substation area controlling for storage for connected grid had better efficiency and optimization of generating power from renewable solar farm and wind turbine which have interconnected distribution power system in the nearby are balance of controlling of the original system.
การผลิตไฟฟ้าจากความร้อนสูญเสียของเตาแก๊สด้วยชุดกำเนิดไฟฟ้าเทอร์โมอิเล็กทริค
This research aimed to study powe generation from heat loss strove by thermoelectric generator unit. As cooking with a gas stove can cause heat loss between the stove and the cookware this heat loss from gas stove can be converted into the electricity. For the experiment the researcher used a gas stove model KB5 installed with thermoelectric plate model TEG1-241-1.4-1.2 connected in a series to the power of 4 modules. Then experimental conditions of the gas pressure in the gas strove were set at 0.1 0.2 0.3 0.4 0.5 and 0.6 kg/cm2 respectively while the amount of mixed air was constant during the experiment. The results showed that when the gas pressure was at 0.6 kg2 the temperatures of the hot side and cold side of the thermoelectric generator was equal 250.5oC and 65.5oC respectively. Lt also generated the highest electric power of 53.3 watts. The power conversion efficiency was 5.3% at 38.1 Volts with 1.4 Amperes. In addition when electric was connected to a thermoelectric generator unit with 12 VDC 7-watt LED bulb the gas pressure in the gas stove were set at 0.3 0.4 0.5 and 0.6 kg/cm2 respectively was affected by the difference between the heating temperature and the cold temperature in the range of 185o C that could lighten up LED bulb.
เครื่องกำเนิดไฟฟ้า 5 เฟสแบบเส้นแรงแม่เหล็กไหลตามแนวแกนเพลาขนาด 1 กิโลวัตต์ ประยุกต์ใช้กับพลังงานลมผลิตไฟฟ้า
This research project presents about the design and construction of a five-phase generator for producing magnetic force along the shaft axis that there are various important elements which should be considered in the processes of the design and construction such as flux per pole number of poles number of turns rotor speed and winding coefficient of coils. The experiment result is found that the five-phase axial flux permanent magnet generator along the shaft axis can produce DC voltage by the efficiency without load and with load. Furthermore this contribution can be used to produce electricity with other renewable energy such as electricity from wind energy.