จำนวน Repository ( 3 )

ศึกษาตัวแปรที่มีผลต่อท่อความร้อนที่ติดตั้งวัสดุพรุนชนิดตาข่าย
ศึกษาตัวแปรที่มีผลต่อท่อความร้อนที่ติดตั้งวัสดุพรุนชนิดตาข่าย

This research aims to study the parameters have affected the pipe which was studied the heat transfer characteristics of a heat pipe with a mesh wick. The heat pipe made from copper tubes with intemal (ID) as 10 and 12 mm and length of 30 cm which was installed a copper mesh wick inside a tube. Three working fluids are distilled water ethanol and refrigerants-11 (R-11). The filling ratios is 50% with respect to evaporator volume. The operating temperature at the evaporator section is: 50 70 and 90 oC. The condenser section has cooked by water with a flow rate of 0.5 L/min. Then all of the experimental data were compared with the heat pipe without copper mesh wick. It was found that heat pipe at ID 12 mm yielded a better heat transfer rate when compared with heat pipe without a mesh wick. The heat pipe produced a heat transfer rate value of 7.3 W and heat pipe efficiency of 58.5 at evaporator section’s temperature of 90oC. In addition the mesh wicks will help transfer the working fluid in the condenser section return to the evaporator section. The condensed liquid had spread around the walls of the heat pipe. The working fluid was condensed to the evaporator section then affected to a higher heat transfer rate.

2563
การทำนายอัตราการถ่ายเทความร้อนในเงื่อนไขสถานะชั่วครู่ของเครื่องแลกเปลี่ยนความร้อนชนิดท่อความร้อนโดยใช้แบบจำลองสามมิติ
การทำนายอัตราการถ่ายเทความร้อนในเงื่อนไขสถานะชั่วครู่ของเครื่องแลกเปลี่ยนความร้อนชนิดท่อความร้อนโดยใช้แบบจำลองสามมิติ

The aim of this study was to develop a three-dimensional transient condition model to predict the heat transfer rate of a heat pipe heat exchanger. This paper presents the details of the calculated domains which consist of the wall wick and vapor core. They were numerically simulated using the finite element method. The heat transfer rate values obtained from the model simulation can be used to design heat pipe heat exchangers. The values obtained from the model calculation were then compared with the results from experiments and the differences were 10.3% 10.4% and 6.7% for the working fluids of distilled water ethanol and R134a respectively. The working fluids of distilled water ethanol and R134a obtained heat transfer rates of 627.3 watts 522.8 watts and 836.4 watts from the experiments respectively.

2559
Two-dimensional transient model for prediction of temperature profile at heat pipe wall
Two-dimensional transient model for prediction of temperature profile at heat pipe wall

Distribution trend of transient temperature profile of copper heat pipe from the start-up of outer wall temperature of evaporator section until the temperature was steady was studied. A two-dimensional model used numerical solution which based on finite difference method. The transient temperature distributions measured in all 3 heat pipe sections were compared with results from the numerical solution of the two-dimensional model that utilized the concept of temperature distribution in the pipe wall during transient operation. Results showed that the experimental trend and the theoretically predicted temperature profiles were similar. Moreover there was good agreement when compared with the numerical simulation of Mistry et al. (2010). Therefore the numerical-validated heat pipe temperature distributions were successfully simulated in a two-dimensional model.

2557