จำนวน Repository ( 13 )
การแปลงหน้าที่ทางคุณภาพเพื่อพัฒนาผลิตภัณฑ์ผลิตไฟฟ้าจากลมระบายความร้อนของเครื่องปรับอากาศ
This research had the objective to design and develop power production from daily life leftovers for their highest benefit of utilization by using the principle of quality function development and power generator that changed mechanical energy into electric energy. In developing electric generator product from air conditioner condensing unit the researcher found that there were 4 important factors including speed installation distance size and cross-sectional area of the fan and the test was conducted between 8.00-17.00 hours. The researcher collected the data and analyzed the test result and found that the best result in the test was to install the product at the distance of 10 cm by using an 18 fan in order to acquire the best voltage and the data were collected so that they could be implemented in developing such product in the future.
ปัจจัยที่มีผลต่อการพัฒนาแผ่นกรุผนังเพื่อลดภาระการใช้พลังงานของเครื่องปรับอากาศภายในอาคารเพื่อต่อยอดเชิงพาณิชย์
This research approach to study the development of interior wall for reduce energy consumption by air conditioning in the building. In order to be a prototype in the development of an industrial system for the export of green architecture in order to generate income for the community or entrepreneurs to bring money into the country to upgrade the industrial economy to be sustainable It is an architectural material that is compatible with the weather in Thailand. It can be used as a guideline for people interested in applying it to their own home building or disseminating through various media to reduce energy costs for a comfortable living. The objective is to study the factors that affect the development of wall paneling in order to reduce the energy burden of the air conditioner in the building in order to further the commercial production. The researcher collected data for the past 6 months not including other thermal energy. Used to calculate the energy consumption index for 2 building groups it was found that the electricity consumption of green buildings were 531100 kilowatt hours. And an average of 5.31 kilowatt hours per square meter While the non-green building has an average of 653360 kilowatt hours. And an average of 6.53 kilowatt hours per square meter As for the results of the data analysis the damage level is mostly at level 1 which is the wall surface and no obvious damage. Especially the 4th and 5th height is 1.55 meters and 1.85 meters from the floor level in the building. Damage level 3 is found at the height level 3 at a height of 1.00 meters from the floor level in the building. Assessment of damage caused to the interior wall of the building that occurred in 3 levels. The results of the data analysis showed that most damage levels were at level 1 namely the wall surface without obvious damage. Especially the 4th and 5th height is 1.55 meters and 1.85 meters from the floor level in the building. Damage level 3 is found at the height level 3 at a height of 1.00 meters and from the results of collecting moisture content in the exterior wall materials And analyzed to find the average for each of the 5 levels of height which are 0.55 meters 0.75 meters 0.95 meters 1.55 meters and 1.85 meters found that the buildings have different moisture content in each wall level (p <0.05). In conclusion this green building index equation can be applied to other buildings to reduce energy consumption and meet the standards of the green building. From the equation the electricity consumption can be predicted using the electricity usage index and systematically designed energy management in buildings. The area with the most damage will find the humidity in the range of 47% -98% the highest damage level 3 at an elevation of 0.80 meters from the floor level in the building
การเพิ่มการถ่ายเทความร้อนของถังน้ำร้อนในระบบผลิตน้ำร้อนที่ใช้พลังงานความร้อนทิ้งจากเครื่องปรับอากาศ
This research is to study in heat transfer of hot water tank from an air conditioner which is a cylinder type and has a hot water pipe around the tank. It is used for finding a position and a pattern of distribution of the hot water pipe around the tank in the highest heat transfer condition. The study uses the cylinder of hot water tank filled 45 liters of 25 oC water. An experiment separates in 3 positions of pipe wrapping which are the bottom the center and the top of the tank. Then 80 oC of hot water run thought the hot water pipe which is wrapped around the tank for 120 minutes. The result of the experiment shows that tubing position that causes the highest heat transfer is at the bottom of tank. Pipe wrapping at the bottom of the tank has the heat transfer higher than the top of the tank at 30%. Furthermore this experiment studies in spacing of hot water pipe. There are 3 types for testing which are spacing hot water pipe as one time two times and three times of diameter of pipe. The result illustrates that spacing the hot water pipe can significantly increase the heat transfer. The heat transfer of spacing the hot water pipe in three times of diameter of pipe is higher 5.8 % than spacing in one times. In addition this research is to study in the effect of turbulent flow on the heat transfer by installing agitator in order to stir water in the tank. The result is that water stirring in the tank for increasing the heat transfer is not effective for investment because the energy using for stirring is higher than the enhanced heat transfer
การพัฒนากระบวนการเชื่อมท่อทองแดงระบบสารทาความเย็นเครื่องปรับอากาศโดยใช้โต๊ะเชื่อมแบบหมุน
The objectives of this research are to develop the welding process of copper tube for refrigeration in air conditioner by using rotation brazing table. The key design is the use of rotary head for nitrogen and rotary head for cooling water in assembly jig nitrogen discharge to prevent the internal welding soot to remove the soot that may occur during welding from piping system and to cool down the profile quickly. The result of water cooling to prevent that damage due to the heat of welding. The result from designing and creating of rotation brazing table to substitute stationary welding found that there is the reduction of machine cost by 11.61% or 46000 Baht/machine reduction of usage space 8.75 square meters or 74375 Baht increase of productivity by 93.48% reduction of nitrogen consumption by 98.20% or 2593 Baht/month reduction of support tool in production 75000 Baht per one rotation brazing table reduction of tiredness from working by 30.24% or equal to 137 manual works per day and reduction of usage of consumable material that can cause of greenhouse gas in form of trash such as cloth glove 1.40 KgCo2 per year leather glove 12.5216 KgCo2 per year nitrogen gas 0.1784 TonCo2 per year and water 0.54 KgCo2 per year. All of these can support the competition and dynamic change of industrial air conditioner in the future sustainably.
การเลือกบำรุงรักษาเครื่องปรับอากาศแบบแยกส่วนตามสภาพ โดยพิจารณาจากค่าอัตราส่วนประสิทธิภาพพลังงาน (EER)
This research was studied to determine the optimum value for condition based maintenance of split type air conditioner by measuring the temperature humidity and flow of air through the fan coil unit. Measuring electric current and voltage of split type air conditioner. Find the energy efficiency ratio (EER) based on the actual use compared to the EER was determined by the manufacturer. To find the suitable maintenance and cleaning air conditioner for each. In conducting this research is split type air conditioner. Rated cooling 25000 Btu/hr. Rated power 2291 watts. Rated current 9.89 amperes. Rated voltage 220 volts single phase. Using the refrigerant R-22.EER 11.02Btu/hr/watts. Running 24 hour sperdayat a temperature of 18°C. Research indicates that the EER before maintenance is equal to6.23Btu/hr/watts. After maintenance is the EER of 20.2Btu/hr/watts or EER value the increase was 69%. Thus preserving the EER of air conditioner. The condition based maintenance in reasonable time is one way that can help save energy.