การเลือกบำรุงรักษาเครื่องปรับอากาศแบบแยกส่วนตามสภาพ โดยพิจารณาจากค่าอัตราส่วนประสิทธิภาพพลังงาน (EER)
การเลือกบำรุงรักษาเครื่องปรับอากาศแบบแยกส่วนตามสภาพ โดยพิจารณาจากค่าอัตราส่วนประสิทธิภาพพลังงาน (EER)

This research was studied to determine the optimum value for condition based maintenance of split type air conditioner by measuring the temperature humidity and flow of air through the fan coil unit. Measuring electric current and voltage of split type air conditioner. Find the energy efficiency ratio (EER) based on the actual use compared to the EER was determined by the manufacturer. To find the suitable maintenance and cleaning air conditioner for each. In conducting this research is split type air conditioner. Rated cooling 25000 Btu/hr. Rated power 2291 watts. Rated current 9.89 amperes. Rated voltage 220 volts single phase. Using the refrigerant R-22.EER 11.02Btu/hr/watts. Running 24 hour sperdayat a temperature of 18°C. Research indicates that the EER before maintenance is equal to6.23Btu/hr/watts. After maintenance is the EER of 20.2Btu/hr/watts or EER value the increase was 69%. Thus preserving the EER of air conditioner. The condition based maintenance in reasonable time is one way that can help save energy.

2559
การเพิ่มประสิทธิภาพเครื่องปรับอากาศแบบแยกส่วนโดยใช้ลมเย็นจากพัดลมระบายอากาศ
การเพิ่มประสิทธิภาพเครื่องปรับอากาศแบบแยกส่วนโดยใช้ลมเย็นจากพัดลมระบายอากาศ

This research aimed to find the possibility of increasing the efficiency of the split type air conditioner by using the cool air from a ventilation fan in the air conditioning room for cooling the condenser. Two simulation rooms size 120x120x200 centimeters were constructed. The first room was installed the evaporator and the second room was installed the condenser and a ventilation fan in the lower part of the air conditioning room to deliver the cool air for cooling the condenser. Then the system was tested and compared the energy efficiency ratio and the reduced power consumption between turning on and turning off a ventilation fan. The results of the proposed air conditioner system observed from the various load conditions at 0% 30% 60% and 100% The surrounding temperature of the condenser ranged in 30C 40C and 50C It was found that the energy efficiency ratios increased in the range of 2.94% to 5.92% and the power consumptions decreased in the range of 4.56% to 12.5% The possibility of increasing the efficiency of the air conditioner system by using the cool air from ventilation fan in the air conditioning room for cooling the condenser was verified by the increased energy efficiency ratios and the reduced power consumptions.

2559
To study the energy efficiency of air conditioners and hybrid air conditioners
To study the energy efficiency of air conditioners and hybrid air conditioners

This paper presents the results of tests to study the energy efficiency of air conditioners Split 9000 BTU test the air in normal operation and when the tune parts. of Evaporator units use DC power from solar energy. Power of the test in normal operating conditions the air power and average about 820 watts on system configuration and operation of Evaporator units. 645 air watts average power consumption can be reduced up to 175 watts of electricity equivalent to 21.34% of them compare the energy efficiency of the air conditioner from the label number 5 on the test. The energy efficiency of a 14.41 11.55 a 24.76% increase in energy efficiency

2558