จำนวน Repository ( 7 )
การจำลองทางคณิตศาสตร์เปรียบเทียบกับการปฏิบัติการโรงไฟฟ้าพลังงานแสงอาทิตย์ขนาดเล็กแบบกระจายตัวในระบบจำหน่าย
This paper presents a mathematical simulation to compared to operations a small distributed photovoltaic power plant in the distribution system. Practices transmission of electric power by small distributed solar energy With the PVSyst and IEC 61724 mathematical modeling programs the main objective was to study the % performance ratio photovoltaic power plants 5.95 MWp connected in the distribution system of the Provincial Electricity Authority voltage level 22 kV. Therefore this paper is presented as a mathematical simulation compared to operations a small distributed photovoltaic power plant in a distribution system. The results of the study show that the operation of small distributed solar power plants increases the efficiency to be able to produce the maximum electricity and continuously. The system was able to produce the highest power of 8954.9 MWh/year and had an average annual efficiency ratio of 77.84% receiving the highest solar radiation intensity and the highest annual total energy output of approximately 1837 kWh/m2
การวิเคราะห์ปัญหาน้ำเสียที่มาจากกากการเผาไหม้ของเหง้าทลายปาล์มที่โรงไฟฟ้าพลังงานชีวมวลและพลังงานก๊าซชีวภาพเพื่อหาแนวทางควบคุมคุณภาพน้ำด้วยระบบไฟฟ้าแรงดันสูง
This research study analyzes the problem of waste water from the burning of palm trees which are used as fuel for power generation of palm ash. It is used to ferment biogas as a fuel for power generation where a large amount of wastewater from the gas digester is completed. The wastewater is then pumped out of the gas digester. Biological in large quantities Therefore to study the analysis of wastewater to find a method for designing a wastewater treatment system from high voltage systems from the corona discharge principle when adding ozone it is necessary to analyze the chemical effects of the wastewater according to the standard values of the Department of Industrial Works.
การศึกษาสมรรถนะของโรงไฟฟ้าไตรแลทเทอร์รัล ซับคริติคัล โออาร์ซี และซุปเปอร์คริติคัล โออาร์ซี โดยใช้แหล่งความร้อนใต้พิภพเป็นแหล่งพลังงาน
This study investigates three different types of power plant include a trilateral cycle (TLC) subcritical organic Rankine cycle (ORC) and supercritical ORC power plant driven by geothermal heat source with mass flow rate 1 kg/s and temperature of 100๐C 110๐C and 120๐C. with 27 substances were examined as the working fluid of the power plant. While the net power output of 4.78 kW and 7.74 kW is obtained from the subcritical ORC with RC318 as its working fluid when the heat source temperature are at 100๐C and 110๐C respectively. Meanwhile the net power output of 11.85 kW is obtained from the subcritical ORC with R227ea as its working fluid when the heat source temperature is at 120๐C. The net power output of 5.64 kW and 9.16 kW are obtained from the supercritical ORC with R218 as its working fluid when the heat source temperature are at 100๐C and 110๐C respectively. Meanwhile the net power output of 12.88 kW is obtained from the supercritical ORC with R143a as its working fluid when the heat source temperature is at 120๐C. Furthermore the net power output of 7.96 kW 12.27 kW and 17.38 kW are obtained from the TLC plant with heptane as its working fluid when the heat source temperature are at 100๐C 110๐C and 120๐C respectively.
การศึกษาเชิงเปรียบเทียบระหว่างโรงไฟฟ้าโออาร์ซีแบบซับคริติคัลโรงไฟฟ้าโออาร์ซีแบบซุปเปอร์คริติคัล และโรงไฟฟ้าแรงคินไซเคิลแบบไตรแลทเตอรัลสำหรับแหล่งความร้อนที่อุณหภูมิ 210-250 องศาเซลเซียส
The performance investigations of subcritical ORC supercritical ORC and trilateral Rankine cycle (TLC) power plants with the heat source temperatures of 210-250°C were conducted and compared in this study. Several working fluids were evaluated. A MATLAB code was developed and used in this study. The thermodynamic properties of the working fluids were calculated by using NIST REFPROP program. The justification of the code was validated with a result taken from the literature. The optimal operating conditions were searched using the golden-section technique. The maximum net output power of 141.72 kW was obtained when using the supercritical ORC plant with R141b as its working fluid and the heat source temperature was at 250°C. The corresponding cycle efficiency was 16.25%. When using the subcritical plant at the same heat source temperature the maximum net output power of 133.40 kW and cycle efficiency of 15.70% are obtained when pentane is used as the working fluid. Furthermore the net output power of 133.82 kW and cycle efficiency of 14.90% are obtained when using R141b as the working fluid in the TLC power plant. According to the off-design simulations an appropriate adjustment of the working fluid flow rate can mitigate the variation of the net output power.
การทดสอบสมรรถนะของเครื่องขยายไอแบบสโครลสำหรับโรงไฟฟ้าโออาร์ซีขนาด 1 กิโลวัตต์
The ORC power plant is a promising technology to generate electricity from low-temperature heat sources. However implementation of the ORC for low capacity electricity generation is unattractive at the commercial level. Scroll compressors are massively produced to be used in refrigeration and air-conditioning applications. Using a scroll compressor in reverse as an expander can reduce the investment cost of low-capacity ORC power plants. In this study 2 scroll compressors that are available in the automotive air-conditioning market of Thailand were modified and used as the expander of a 1 kW ORC power plant. The performances of these 2 scrolls were compared and the plant performance was investigated. A heat source temperature from 100°C to 150°C was supplied to the plant. It was found that the gross power is higher by 18-35% for the larger expander (110 cc/rev) than for the smaller expander (85.7 cc/rev). The larger one provides the isentropic efficiency of 37-76% and the gross power of 806-1926 W. In addition the effects of check valve installation were examined and compared with those of the tests without check valve installation. It was revealed that the isentropic efficiency increases by 18% while the gross power decreases by 4-22% when the check valve was installed.