จำนวน Repository ( 2 )
กำลังอัดความสามารถเก็บกักคลอไรด์และสัมประสิทธ์การแพร่คลอไรด์ของคอนกรีตผสมเถ้าก้นเตาบดละเอียดและผงหินปูน
This research was aimed to study the compressive strength chloride binding capacity and chloride diffusion coefficient of concrete replaced by ground bottom ash (GBA) and limestone powder in ordinary Portland cement (OPC). The water to binder ratios were 0.55. The results showed that the compressive strength of concrete with GBA was lesser than that of OPC concrete at 28 days. Also the compressive strength of concrete with limestone powder was close to that of OPC concrete and compressive strength could develop of concrete with GBA 20% and 30% higher than that of OPC concrete at 56 days. Moreover the total chloride of the concrete containing GBA and limestone powder was less than that of OPC concrete. The chloride penetration of the concrete containing GBA and limestone powder was less than that of OPC concrete. The chloride binding capacity of the concrete made with ground bottom ash and limestone powder were higher than that of OPC concrete. Finally the chloride diffusion coefficient of the concrete containing GBA and limestone powder was less than that of OPC concrete.
การเสริมกำลังคานลึกคอนกรีตเสริมเหล็กที่เสื่อมสภาพเนื่องจากคลอไรด์ด้วยแผ่นคาร์บอนไฟเบอร์
Deterioration of reinforced concrete deep beam structure caused by chloride is severe andtakes up wide area even though the structure is not exposed to sea water or brackish water. Even the structure which is far from sea water or brackish water is affected by this problem.When the reinforced concreate deep beam structure is affected by chloride steel reinforced inside the structure is corroded resulting in reducing the cross-sectional area of the reinforced steel affecting load capacity deflection and beam failure. If there is no repair or strengthening such capabilities are continuously reduced until it is no longer safe to use the beam. Therefore it is necessary to repair or strengthening the deteriorated structure to be safely used. This research investigated strengthening of deteriorated reinforced concrete deep beam caused by chloride with 4 formats of carbon Fiber sheets to seek guidelines for the most efficient strengthening. The resultshowed that the strengthening by the 4 format of carbon fiber sheet could increase ultimate loadcapability yet could not improve ductility of the deteriorated beam to become close to the beamthat is not deteriorated. The strengthening that could increase the maximum ultimate load capability was the table format strengthening. In addition the strengthening that the carbon fiber making 45 degrees with the length of the beam could best prevent diagonal cracks.