Effectiveness investigation of evaporative cooling using radiator for pre-cooling system
Effectiveness investigation of evaporative cooling using radiator for pre-cooling system

Due to the systems of mechanical vapor compression have a high energy consumption for air-conditioned space. Therefore the system of evaporative cooling presents as a promising alternative option for the air-conditioning system. Moreover the pre-cooling system is normally used to reduce an intake ambient air temperature before the air-conditioning system. As mentioned above this research aims to investigate the effectiveness of evaporative cooling system by using a car radiator for air per-cooling. In this research the commercial car radiator was used for cooling inlet ambient air by cooling water. The evaporative cooling system consisted of evaporative cooling panel with a maximum water rate of 40 lite/minute and a maximum air rate of 5100 m3/hr. The results show that most suitable water flow rate of radiator is 10 lite/minute and this radiator can make the differences of air temperature of about 8.9oC. Moreover the results also show that the effectiveness of evaporative cooling system could reach about 73.31% with a maximum sensible heat of 8.43 kW.

2563
Effects of environmental management in evaporative cooling system (EVAP) house on productive performance of layer pullets
Effects of environmental management in evaporative cooling system (EVAP) house on productive performance of layer pullets

The research was conducted to study on effects of environmental management in evaporative cooling system (EVAP) house on productive performance of layer pullets. This study divided into 2 experiments. Experiment 1 was conducted to study on temperature and air velocity in evaporative cooling system (EVAP) house on productive performance of layer pullets. Four thousand and eight hundred layer pullets were raised on battery cage with 5 birds per cage and assigned in a Randomized Completely Block Design (RCBD) experiment with three treatments. Each treatment consisted of four blocks (four houses) and followed different temperature and air velocity in raising area of evaporative cooling system (EVAP) house as front area central area and back area. Results showed that temperature and air velocity in front area was grater body weight gain (BWG) average daily gain (ADG) and feed conversion ratio (FCR) of layer pullets than layer pullets were raised in back area of evaporative cooling system (EVAP) house (P<0.01) Experiment 2 was conducted to study on light color and number of H-Flame battery cage row in evaporative cooling system (EVAP) house on light intensity and productive performance of layer pullets. Nine thousand and six hundred layer pullets were raised on H-Flame battery cage with 5 birds per cage and assigned in a 2x4 factorial in Randomized Completely Block Design (RCBD) experiment with two factors. Factor A was light color comprised of range and blue). While Factor B was number of battery cage row comprised (first row second row third row and fourth row). Each treatment consisted of four blocks (four houses). Results showed that interaction between factor A and B on light intensity and uniformity of layer pullets with highly significantly different (P<0.01). However interaction between factor A and B and main effect (factor A and B) were investigated on body weight gain (BWG) average daily gain (ADG) and feed conversion ratio (FCR) (P>0.05). The data from this research was suggests the important for implicate to improve the egg production industry in further success.

2558
Temperature Reduction in Hydroponic Planting System Using Heat Pipe
Temperature Reduction in Hydroponic Planting System Using Heat Pipe

This paper presents an establishment of a mathematical model to determine the optimal size of heat pipe (thermosyphon) heat exchanger for reduce the inlet air temperature in evaporative cooling system of greenhouse. The condition of a mathematical model is the total length of heat pipe is 1.5 m. A mathematical model will determine the optimal value of evaporator section and condenser section. The range of evaporator length is 0.5 – 1.4 m with an increment of 0.1 m and condenser length is in range of 0.1 – 1.0 m with an increment of 0.1 m. The inlet air temperature in evaporative cooling of greenhouse is depend on ambient temperature about 35 degree Celsius. While the cooling water temperature is 20 degree Celsius. Evaporative pad of evaporative cooling system is 2 m in width and 7 m in length. From the conditions above the optimize results from a mathematical model are as follows: evaporator section length is 0.9 m and condenser section length is 0.6 m moreover it was shown that investment net saving and maximum heat rate are 79.83 Thousand Baht 0.552 Million Baht and 15.6 kW respectively.

2553