การนำน้ำคอนเคนเซดมาระบายความร้อนให้กับแผงคอนเดนเซอร์ของระบบปรับอากาศ
การนำน้ำคอนเคนเซดมาระบายความร้อนให้กับแผงคอนเดนเซอร์ของระบบปรับอากาศ

Now a day the mostly air condition are use vapor compression refrigeration system in which R-22 refrigerant is used as a working substance. From the results of study it found that the quantity of water vapor or moisture in the air is condensed with in the fan coil unit while through out the evaporator. The fluid after condense is called condensed water. By this process the quantity of condensed water is increases when the air condition is used in the long time. To increase the utility the condensed water is recovered for the heart reduction in the finned-tube condenser. The experiment is consist of two conditions by using the air and condensed water to heart reduction. But in case of condensed watcr the pressure openation is controlled at 280 and 260 Psig respectively. The results of efficicncy ratio (EER) is 39675 Btu/hr 3.01 and 10.3 Btu/hr Watt respectively with the air is used At the pressure operation 280 Psig refrigeration effect (C.O.P) and (EER) is 44212 Btu/hr 3.38 and 11.5 Btu/hr. Watt respectivecly and 49856 Btu/hr 3.99 and 13.6 Btu/hr Watt at pressure operation 260 Psig. Furthermore the capacity of condenser is increases to 11.43% and 25.6% and also the refrigerant efficient is increases to 12.43 % and 32.43% at the pressure operation 280 and 260 Psig. Thus the pararneter of energy efficiency ratio depends on the capacity of condenser working substance temperature (pressure operation) and air surrounding tcmperature.

2555
Finned-tube Condenser Cleaner Machine
Finned-tube Condenser Cleaner Machine

Now a day the mostly air condition are use the air for reducing the temperature at the condenser unit. Moreover many dusts are adhering in area of fin coil. From this reason the heart reduction efficiency is decreased and increasing the energy consumption. Thus the aim of this research is to design the finned-tube condenser unit cleaner machine for increasing the heart reduction efficiency. From the results of experiment it found that the finned-tube condenser cleaner machine is desirable when comparing with the performance before used. By the original performance the refrigeration effect coefficient of performance (C.O.P) and energy efficiency ratio (EER) is 34179 Btu/hr 2.62 and 8.9 Btu/hr.Watt. On the other hand the refrigeration effect (C.O.P) and (EER) is 39766 Btu/hr 3.12 and 10.7 BtuIhr.Watt respectively when the condenser unit cleaner machine is used. Based on this condition the value of the refrigeration effect and (EER) are increase to 16.35% and 19.19% respectively. Thus the heart reduction in condensing unit can be aided the performance and prolong the life time of air condition by depending on the cleaning of condensing unit.

2553
A Modeling of Heat Transfer in Cooling Coil using Finite Element Method
A Modeling of Heat Transfer in Cooling Coil using Finite Element Method

In general for the refrigeration the cooling coil is almost used to be the device to decrease the temperature. Thus in order to design heat exchange we should study the heat transfer into the cooling coil. This research proposes the numerical using finite element method for calculating the temperature at any position of the cooling point for considering to porous media. After that to create an algebraic equation fmite element for writing the program to search the solution by estimating the temperature. The research demonstrates that the changing of temperature will be decreased to saturated condition that is the temperature around the region of the cooling coil model edge will be decreased. The longer time the lower temperature around each position will decrease respectively until the temperature at each position inside the model are the same as region of the cooling coil model edge. Therefore this search result can be the basic for the comparison with the similar problem of other

2553
Finned-Tube Condenser Cleaner Machine
Finned-Tube Condenser Cleaner Machine

Now a day the mostly air condition are use the air for reducing the temperature at the condenser unit. Moreover many dusts are adhering in area of fin coil. From this reason the heart reduction efficiency is decreased and increasing the energy consumption. Thus the aim of this research is to design the finned-tube condenser unit cleaner machine for increasing the heart reduction efficiency. From the results of experiment it found that the finned-tube condenser cleaner machine is desirable when comparing with the performance before used. By the original performance the refrigeration effect coefficient of performance (C.O.P) and energy efficiency ratio (EER) is 34179 Btu/hr 2.62 and 8.9 Btu/hr.Watt. On the other hand the refrigeration effect (C.O.P) and (EER) is 39766 Btu/hr 3.12 and 10.7 Btu/hr.Watt respectively when the condenser unit cleaner machine is used. Based on this condition the value of the refrigeration effect and (EER) are increase to 16.35% and 19.19% respectively. Thus the heart reduction in condensing unit can be aided the performance and prolong the life time of air condition by depending on the cleaning of condensing unit.

2550
Using Condensate Water to Reduce Heat for Finned-Tube Condenser of Air Conditioning System
Using Condensate Water to Reduce Heat for Finned-Tube Condenser of Air Conditioning System

Now a day the mostly air condition are use vapor compression refrigeration system in which R-22 refrigerant is used as a working substance. From the results of study it found that the quantity of water vapor or moisture in the air is condensed with in the fan coil unit while through out the evaporator. The fluid after condense is called condensed water. By this process the quantity of condensed water is increases when the air condition is used in the long time. To increase the utility the condensed water is recovered for the heart reduction in the finned-tube condenser. The experiment is consist of two conditions by using the air and condensed water to heart reduction. But in case of condensed water the pressure operation is controlled at 280 and 260 Psig respectively. The results of experiment shown the refrigeration effect coefficient of performance (C.O.P) and energy efficiency ratio (EER) is 39675 Btu/hr 3.01 and 10.3 Btu/hr.Watt respectively with the air is used. At the pressure operation 280 Psig refrigeration effect (C.O.P) and (EER) is 44212 Btu/hr 3.38 and 11.5 Btu/hr.Watt respectively and 49856 Btu/hr 3.99 and 13.6 Btu/hr.Watt at pressure operation 260 Psig. Furthermore the capacity of condenser is increases to 11.43% and 25.6% and also the refrigerant efficient is increases to 12.43% and 32.43% at the pressure operation 280 and 260 Psig. Thus the parameter of the energy efficiency ratio depends on the capacity of condenser working substance temperature (pressure operation) and air surrounding temperature.

2550