Experimental investigation of a thermosyphon economizer to recover waste heat in the electronics industry
Experimental investigation of a thermosyphon economizer to recover waste heat in the electronics industry

A case study was conducted to design construct and test a thermosiphon economizer for increasing the temperature of feed water by using waste hot water. The simulation of the thermosiphon economizer (heat exchanger) for the establishment of the optimum size was performed using the thermos-economical method. The thermosyphon was made of a total of 80 copper tubes (outside diam.19.05 mm) with evaporative adiabatic and condensation lengths of 300 10 and 300 mm respectively. The working fluid was R-134a filling ratio was 50% by evaporative volume and the thermosiphon was arranged in a staggered form. In testing performance flow rate of the inlet hot water was set at 10 L/min and the controlled inlet temperature of cold water at 25oC. The average flow rate of the cold water was set at 5 7 and 10 L/min respectively. Results showed that the maximum of rate of heat transfer from the condenser section occurred at the flow rate of the cold water of 10 L/min. When test the inlet temperature of hot water of 4555 and 65 o C were used at the inlet volume flow rate of cold water of 10 L/min maximum heat transfer rates from the condenser 4626 8260 and 8790 W were achieved. Moreover the outlet temperature of the cold water which was initially 25o C changed to 311 34 and 37o C respectively. Therefore increasing the outlet feed water temperature reduced energy consumption. The effectiveness of the thermosiphon economizer with the inlet temperatures of hot water of 45 55 and 65o C was 0.47 0.48 and 0.49 respectively.

2563
Performance Analysis of Adsorption Refrigeration System with Water-Thermosyphon Cool Adsorber and Evaporator Enhanced with Near-Ultrasonic Wave
Performance Analysis of Adsorption Refrigeration System with Water-Thermosyphon Cool Adsorber and Evaporator Enhanced with Near-Ultrasonic Wave

Here we present an experimental study of the single-effect adsorption cooling system using activated carbon-methanol working pair. The test unit was comprised of an adsorber a condenser and evaporator in vertical alignment. Heating and cooling of adsorber was mainly done by hot and cold water circulating through the water jacket. The evaporator and condenser was heated or cooled by flows of water through the internal coil. The adsorber was analyzed for its cooling rate when cooling was done by two approaches either cooling water and/or three thermosyphon heat pipes which both methods gave shortest cooling time. The investigated heat source and sink temperatures are; hot water temperature supplied to adsorber (70 80 90 oC) and cooling water temperature supplied to condenser (5 10 15 oC). An ultrasonic wave generator was attached to the bottom end of the evaporator to generate wave frequency varied by 8 10 and 14 kHz during evaporation phase. The ultrasonic wave can obviously reduce the evaporation time of methanol as well as to improve the system performance in terms of COP SCP and VCP. The system performance was considerably comparable to those from literatures. The highest COP and SCP obtained from this system was 0.718 and 248.90 W/kg respectively.

2553
Temperature Reduction in Hydroponic Planting System Using Heat Pipe
Temperature Reduction in Hydroponic Planting System Using Heat Pipe

This paper presents an establishment of a mathematical model to determine the optimal size of heat pipe (thermosyphon) heat exchanger for reduce the inlet air temperature in evaporative cooling system of greenhouse. The condition of a mathematical model is the total length of heat pipe is 1.5 m. A mathematical model will determine the optimal value of evaporator section and condenser section. The range of evaporator length is 0.5 – 1.4 m with an increment of 0.1 m and condenser length is in range of 0.1 – 1.0 m with an increment of 0.1 m. The inlet air temperature in evaporative cooling of greenhouse is depend on ambient temperature about 35 degree Celsius. While the cooling water temperature is 20 degree Celsius. Evaporative pad of evaporative cooling system is 2 m in width and 7 m in length. From the conditions above the optimize results from a mathematical model are as follows: evaporator section length is 0.9 m and condenser section length is 0.6 m moreover it was shown that investment net saving and maximum heat rate are 79.83 Thousand Baht 0.552 Million Baht and 15.6 kW respectively.

2553