จำนวน Repository ( 15 )
การแปลงหน้าที่ทางคุณภาพเพื่อพัฒนาผลิตภัณฑ์ผลิตไฟฟ้าจากลมระบายความร้อนของเครื่องปรับอากาศ
This research had the objective to design and develop power production from daily life leftovers for their highest benefit of utilization by using the principle of quality function development and power generator that changed mechanical energy into electric energy. In developing electric generator product from air conditioner condensing unit the researcher found that there were 4 important factors including speed installation distance size and cross-sectional area of the fan and the test was conducted between 8.00-17.00 hours. The researcher collected the data and analyzed the test result and found that the best result in the test was to install the product at the distance of 10 cm by using an 18 fan in order to acquire the best voltage and the data were collected so that they could be implemented in developing such product in the future.
การศึกษาความเหมาะสมของการใช้ระบบปรับอากาศในสำนักงานเพื่อการอนุรักษ์พลังงานและสภาวะความสบาย
Presently Rental office is famous in downtown that near food center and have good transportation. In Thailand office buildings usually have operating time 8-10 hours per day. So need to improve the building for energy conservation and employee’s comfort. Glasses are one way that heat transfers occur highly. Overall Thermal Transfer Value (OTTV) is a tool for measure heat transfers through building envelope. From OTTV calculation for existing building OTTV is 92.94 W/m2 that over ministerial regulations indicate 50 W/m2. Improving building envelope by add more thickness of glasses can reduce OTTV 1.3% and improving building envelope by film installation can reduce OTTV 47.2% and improving building envelope by add shading can reduce OTTV 48.5%. However each improving policy have each investment cost. Conjoint analysis is consider of many factor to find willingness to pay for each choice. So set policies for energy conservation water and waste management and increase comfort are employees to improve energy conservation water and waste management and increase comfort are 19935.90 17590.50 and 1563.60 baht respectively so can improve building envelope by add shading result in OTTV to 47.8 W/m2 Budget 18000 Baht can be improve organization that payback about 5400 Baht per year. Increase thermal comfort by install table fan. From the result of research expect to apply to improve rental office in the future.
ปัจจัยที่มีผลต่อการพัฒนาแผ่นกรุผนังเพื่อลดภาระการใช้พลังงานของเครื่องปรับอากาศภายในอาคารเพื่อต่อยอดเชิงพาณิชย์
This research approach to study the development of interior wall for reduce energy consumption by air conditioning in the building. In order to be a prototype in the development of an industrial system for the export of green architecture in order to generate income for the community or entrepreneurs to bring money into the country to upgrade the industrial economy to be sustainable It is an architectural material that is compatible with the weather in Thailand. It can be used as a guideline for people interested in applying it to their own home building or disseminating through various media to reduce energy costs for a comfortable living. The objective is to study the factors that affect the development of wall paneling in order to reduce the energy burden of the air conditioner in the building in order to further the commercial production. The researcher collected data for the past 6 months not including other thermal energy. Used to calculate the energy consumption index for 2 building groups it was found that the electricity consumption of green buildings were 531100 kilowatt hours. And an average of 5.31 kilowatt hours per square meter While the non-green building has an average of 653360 kilowatt hours. And an average of 6.53 kilowatt hours per square meter As for the results of the data analysis the damage level is mostly at level 1 which is the wall surface and no obvious damage. Especially the 4th and 5th height is 1.55 meters and 1.85 meters from the floor level in the building. Damage level 3 is found at the height level 3 at a height of 1.00 meters from the floor level in the building. Assessment of damage caused to the interior wall of the building that occurred in 3 levels. The results of the data analysis showed that most damage levels were at level 1 namely the wall surface without obvious damage. Especially the 4th and 5th height is 1.55 meters and 1.85 meters from the floor level in the building. Damage level 3 is found at the height level 3 at a height of 1.00 meters and from the results of collecting moisture content in the exterior wall materials And analyzed to find the average for each of the 5 levels of height which are 0.55 meters 0.75 meters 0.95 meters 1.55 meters and 1.85 meters found that the buildings have different moisture content in each wall level (p <0.05). In conclusion this green building index equation can be applied to other buildings to reduce energy consumption and meet the standards of the green building. From the equation the electricity consumption can be predicted using the electricity usage index and systematically designed energy management in buildings. The area with the most damage will find the humidity in the range of 47% -98% the highest damage level 3 at an elevation of 0.80 meters from the floor level in the building
การสร้างและหาประสิทธิภาพชุดสาธิตการจำลองกรณีศึกษาของระบบไฟฟ้าในระบบปรับอากาศ
This project is intended as a teaching medium air conditioning system and simulation of air conditioning system problems. Some of them have been modified to suit their teaching needs. Arduino microcontrollers are used to control the system. By starting the study of the air conditioning system thoroughly. The microcontroller is written to control the operation of devices like the air conditioning system when the system malfunction. It will be used to analyze the problems of air conditioning. The experimental set will display the voltage and current. The connection points of the air conditioning problem analysis. When the symptoms are bad. The analyst can solve the problem by connecting or pressing the button of the device. The results of the project. The test will measure the difference of the air conditioning unit. And read the amount of current and volume in the system. To diagnose abnormalities and choose a solution to the problem from the kit system that can be displayed to solve the problem that the analyst was correct or not with the LED status light. Based on the performance test a demonstration kit for the demonstration of efficiency of the air conditioning system was provided to 10 experienced air conditioning technicians. 80s of issues. The reliability of the demonstration set and the efficiency of the simulator case study of the electrical system in air conditioning systems is acceptable
การพัฒนากระบวนการเชื่อมท่อทองแดงระบบสารทาความเย็นเครื่องปรับอากาศโดยใช้โต๊ะเชื่อมแบบหมุน
The objectives of this research are to develop the welding process of copper tube for refrigeration in air conditioner by using rotation brazing table. The key design is the use of rotary head for nitrogen and rotary head for cooling water in assembly jig nitrogen discharge to prevent the internal welding soot to remove the soot that may occur during welding from piping system and to cool down the profile quickly. The result of water cooling to prevent that damage due to the heat of welding. The result from designing and creating of rotation brazing table to substitute stationary welding found that there is the reduction of machine cost by 11.61% or 46000 Baht/machine reduction of usage space 8.75 square meters or 74375 Baht increase of productivity by 93.48% reduction of nitrogen consumption by 98.20% or 2593 Baht/month reduction of support tool in production 75000 Baht per one rotation brazing table reduction of tiredness from working by 30.24% or equal to 137 manual works per day and reduction of usage of consumable material that can cause of greenhouse gas in form of trash such as cloth glove 1.40 KgCo2 per year leather glove 12.5216 KgCo2 per year nitrogen gas 0.1784 TonCo2 per year and water 0.54 KgCo2 per year. All of these can support the competition and dynamic change of industrial air conditioner in the future sustainably.