จำนวน Repository ( 2 )
A simple method of system response compensation of a near infrared instrument for determining brix value of peaches
A system response of a near infrared (NIR) instrument sometimes changes depending on measuring conditions such as warming up time room temperature and the others. In the last peach experiment we measured NIR spectra over 3 days and spectral differences were observed between spectra measured at the first day and those at the second and third days. Therefore a simple method of system response compensation was examined. As a result of principle component analysis (PCA) of second derivative (2D) spectra of peaches samples were separated into two groups the first-day measured samples and the second and third-day measured ones on the plane consisted of PC1 and PC2. On the hypothesis that average 2D spectrum of each group should be almost the same the difference of the average 2D spectra (2D spectrum) was calculated. Using 2D spectrum 2D spectra of the first-day samples were adjusted to those of the other samples. The data set including the adjusted one is called “compensated 2D data set” hereafter as compared with “original 2D data set”. As results of partial least square (PLS) regressions based on the original and compensated 2D data sets and Brix value of peaches good SEPs of 0.98 °Brix for both cases could be obtained. The number of factors for the calibration model in case of compensated 2D data set was smaller than that in case of original one. It was concluded that the method using 2D spectrum could be used to compensate the difference of system response of an NIR instrument.
Compensation of low frequency oscillation on power system using flexible ac transmission systems devices
This paper presents a study of low-frequency oscillations in compensated electric power systems with Flexible AC Transmission System of the power system frequency using PSAT Tool box To assist in the analysis of the stability of the system When the power transients in power systems is simulated By using standard IEEE 14 bus system as a case study. The Equipment that used to control the swing frequency of the is a flexible electrical power control devices or FACTS are two kinds of serial and parallel. The analysis showed that two models are compared with the time (Time Domain) and see the effect of the Eigen (Eigen Value) of the simulation results show work to see that controls are electrical flexible compensation. of low frequency oscillations in power systems in acceptable coordinates