จำนวน Repository ( 19 )
การวางแผนและปฏิบัติการระบบไฟฟ้ากาลังในสภาวะฉุกเฉิน
This thesis presents an application of particle swarm optimization technique (PSO) to optimal economic dispatch analysis in power system with contingency criteria for management power system operation cost power loss and bus voltage. The objective of optimal economic dispatch for contingency in power system compared with the results of analysis power system in normal case. The study result show that when contingency occur in power system operation cost are rising. In the other hand system stability are decrease.
การควบคุมความถี่ -โหลด ของการเชื่อมต่อระบบการผลิตไฟฟ้าจากโซล่าร์ฟาร์มและกังหันลม
The effects of load frequency control (LFC) of interconnected distribution power system in tie-line substation area load –frequency stability and the frequency respond at distribution generator (DG) are very important for interconnected control power system of tie-line area. The generating power system of solar farm and wind turbine which have interconnected distribution power system in tie-line substation area were tested using 3 simulation parameters: non-controller Automatic Voltage Regulator (AVR) and with Pl Controller. The results showed that there were 3 types of load and frequency changing in the interconnected area: load changed 0.02 p.u. had frequency of load changed 0.025 Hz and large disturbance. Comparisons of load-frequency to respond for steady state the time respond was 7.9 seconds for non-controller 5.4 seconds for AVR and 1.7 seconds for under controlled system at 0.1 p.u using Pl controller. Therefore the Pl controller has better efficiency than non-controller about 31 % and AVR about 16%. It can be concluded that the interconnected distribution power system in tie-line substation area controlling for storage for connected grid had better efficiency and optimization of generating power from renewable solar farm and wind turbine which have interconnected distribution power system in the nearby are balance of controlling of the original system.
การเพิ่มเสถียรภาพของระบบไฟฟ้ากำลังด้วยอุปกรณ์ FACTS
At present the electrical power system has growth and more complicate. Because of the development of the economics and society. An increasing the demand of power transmission line system would be resulted in the stability and reliability. The Flexible AC Transmission System devices: (FACTS) is the equipment which can control the flow of real power. In addition it can gladly encourage the stability and reliability of the power transmission line system. This research proposed the impact of placing power electronics device to increase stability and reliability of power system in order to study the impact of Flexible AC Transmission System devices: (FACTS) devices for the resulting to stability of power system. UPFC devices model which consisted of Static Synchronous Compensator and Static Synchronous Series Compensator that worked as independent voltage source for technique to proposed control the flow of real power and reactive power as well as voltage bus in power system. Testing Simulation power flow control of 5 buses by placing unified power flow control indicated the effective compensation of real power and reactive power in power system.
การควบคุมกำลังไฟฟ้ารีแอคทีฟเพื่อเพิ่มมูลค่าทางเศรษฐศาสตร์ ในระบบไฟฟ้ากำลัง
To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor the higher the value it is necessary to buildings offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate. This research presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4 fifth 5 and sixth 6 precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences. As a result when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 1640-watt making the current decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.8 2.2 flow down from 2.360 rests 0.942 amps of power factor value up from 0.308 to 1.0.
การวิเคราะห์ผลกระทบของฮาร์มอนิกเพื่อแก้ปัญหาเศรษฐศาสตร์ในระบบไฟฟ้ากำลัง
This research proposes technical performance evaluation and economic decence for the combination of harmonic correction devices in Industry. Currently an electronic device is popularly applied in power network. Although it is a higher performance device than the existing device it still causes the power quality issues and then network failure. Especially harmonic disturbance in the network it is a harmonic source that generates harmonic current into the network. Many types and solutions are available in the present time therefore the suitable and optimal financial solution must be considered. A network model for the analysis of harmonic correction devices suitable solutions and optimal financial has been established in the simulation software that bases on the power and Break Even Point (BEP) equations. The results of analysis shown that the performance of harmonic correction devices suitable solution and BEP of investment in match to the using of a detuned filter bank and an active harmonic filter (case 8) thus these information will be valued for the end-user.