จำนวน Repository ( 11 )

การควบคุมกำลังไฟฟ้ารีแอคทีฟเพื่อเพิ่มมูลค่าทางเศรษฐศาสตร์ ในระบบไฟฟ้ากำลัง
การควบคุมกำลังไฟฟ้ารีแอคทีฟเพื่อเพิ่มมูลค่าทางเศรษฐศาสตร์ ในระบบไฟฟ้ากำลัง

To Improvement the power factor is very important. Because the costs are increased or reduced. To Improvement the power factor the higher the value it is necessary to buildings offices and industrial buildings or the fact that the industry needs real power. And reactive power source to operate. This research presents the design and construction of reactive power factor control. Which amounted to 6 working order by the first sequence is divided into three three-phase electrical power system and three consecutive singles phase by active power different. first1 is reactive at 5 kVAr second 2 and third 3 are reactive at 2.5 kVAr forth 4 fifth 5 and sixth 6 precious marine active 0.83 kVAr control. the power factor controller that controls RG3-12 pay Oval active in various sequences. As a result when not equipped with reactive power compensation software to control the power factor. This makes the flow of the high and low Power Factor schedule. When equipped compensate reactive power source to power factor control. Single-phase motor 1 kW and light bulb 1640-watt making the current decline of 14 amps rest 12 amps of the power factor increases from 0.5 to 0.929. When connected to three-phase motor with 2 kW 0.8 2.2 flow down from 2.360 rests 0.942 amps of power factor value up from 0.308 to 1.0.

2563
การควบคุมแรงดันและกำลังไฟฟ้าสำหรับเครื่องกำเนิดไฟฟ้าสามเฟส
การควบคุมแรงดันและกำลังไฟฟ้าสำหรับเครื่องกำเนิดไฟฟ้าสามเฟส

This research presents the simulation of a three-phase generator. The aim is to study and analyze the condition of the generator functions. By simulating the operation of the generator used in factory which use this generator as a backup power source to replace primary power source of electricity-supplier. In this test can start or stop the generator to determine the parameters at that time. The generator is used when the main electrical power distribution error and the generator is disabled when electric power system of electricity-supplier back to normal.

2563
เปรียบเทียบประสิทธิภาพการส่งกำลังไฟฟ้าระหว่างหม้อแปลงแกนอากาศและหม้อแปลงแกนเหล็กของวงจรขยายกำลังคลาสอี
เปรียบเทียบประสิทธิภาพการส่งกำลังไฟฟ้าระหว่างหม้อแปลงแกนอากาศและหม้อแปลงแกนเหล็กของวงจรขยายกำลังคลาสอี

This paper presents the simulation and experimental result of class-E power amplifier. It is often used in designing a high frequency ac power source because its ability to perform the conversion efficiently even at high frequencies with significant reduction of switching losses. This paper aims to compare the transmission performance of electrical power between the air core transformer and iron core transformer which the identical input voltage of 50 VAC. Both transformers are designed to step voltage up (step up transformer) ratio of 1:4.5. The Arduino microcontroller Arduino was used to generate a pulse width modulation (PWM) with operating frequency of 3.74 kHz. IC gate drive TC4422 was used to drive the IRF510 MOSFET. Based on the simulation and experimental results the power loss in air core transformer is 75 percent while power loss in iron core transformer is 0.2 percent. The maximum distance that can transmit electric power of air core transformer is 9.3 centimeters.

2563
แบบจำลองการควบคุมเครื่องกำเนิดไฟฟ้าสามเฟสสำหรับควบคุมแรงดันและกำลังไฟฟ้า
แบบจำลองการควบคุมเครื่องกำเนิดไฟฟ้าสามเฟสสำหรับควบคุมแรงดันและกำลังไฟฟ้า

This project presents the simulation of a three-phase generator. The aim is to study and analyze the condition of the generator functions. By simulating the operation of the generator used in factory which use this generator as a backup power source to replace primary power source of electricity-supplier. In this test can start or stop the generator to determine the parameters at that time. The generator is used when the main electrical power distribution error and the generator is disabled when electric power system of electricity-supplier back to normal.

2561
การปรับปรุงคุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าโดยการเชื่อมต่อแหล่งผลิตไฟฟ้าแบบกระจายตัวพลังงานแสงอาทิตย์
การปรับปรุงคุณภาพไฟฟ้าในระบบจำหน่ายไฟฟ้าโดยการเชื่อมต่อแหล่งผลิตไฟฟ้าแบบกระจายตัวพลังงานแสงอาทิตย์

This thesis presents improving power quality in power distribution system with integration of photovoltaic energy distributed generation having objectives to improve power quality in distribution system model of voltage sag and voltage swell in distribution system model of power loss in distribution system application of mathematical model model of power generation by using solar energy and distributed generation connection technique simulation. In this thesis the power flow was tested with Newton-Raphson algorithm joining with mathematical model. The case study was done by reduction of power loss in distribution system by using techniques of connection of distributed generation joining with model of distribution system 33 bus. The case study about improvement of voltage sag and voltage swell in distribution system used connection techniques of distributed generation joining with model of distribution system 69 bus. The study found that technique of connection of distributed generation that was presented could reduce power loss and showed the percentage of improvement of voltage sag and voltage swell in distribution system especially voltage sag case according to IEEE 1159-1995 standard. This thesis showed that severity level of voltage sag depended on the size and duration of each distribution system model situation by photovoltaic energy distributed generation can reduce voltage sag.

2566