จำนวน Repository ( 3 )

การเลือกบำรุงรักษาเครื่องปรับอากาศแบบแยกส่วนตามสภาพ โดยพิจารณาจากค่าอัตราส่วนประสิทธิภาพพลังงาน (EER)
การเลือกบำรุงรักษาเครื่องปรับอากาศแบบแยกส่วนตามสภาพ โดยพิจารณาจากค่าอัตราส่วนประสิทธิภาพพลังงาน (EER)

This research was studied to determine the optimum value for condition based maintenance of split type air conditioner by measuring the temperature humidity and flow of air through the fan coil unit. Measuring electric current and voltage of split type air conditioner. Find the energy efficiency ratio (EER) based on the actual use compared to the EER was determined by the manufacturer. To find the suitable maintenance and cleaning air conditioner for each. In conducting this research is split type air conditioner. Rated cooling 25000 Btu/hr. Rated power 2291 watts. Rated current 9.89 amperes. Rated voltage 220 volts single phase. Using the refrigerant R-22.EER 11.02Btu/hr/watts. Running 24 hour sperdayat a temperature of 18°C. Research indicates that the EER before maintenance is equal to6.23Btu/hr/watts. After maintenance is the EER of 20.2Btu/hr/watts or EER value the increase was 69%. Thus preserving the EER of air conditioner. The condition based maintenance in reasonable time is one way that can help save energy.

2559
รูปแบบการระบายความร้อนด้วยน้ำที่ส่งผลต่อสัมประสิทธิ์สมรรถนะของระบบปรับอากาศแบบแยกส่วน
รูปแบบการระบายความร้อนด้วยน้ำที่ส่งผลต่อสัมประสิทธิ์สมรรถนะของระบบปรับอากาศแบบแยกส่วน

The purpose of this research was to investigate cooling water profile that effect to coefficient of performance of spilt type air- conditioning system. Air conditioner size of 12000 Btu/h was used in this experiment. There are three experiment of cooling water profiles in this work such as water spray water drop and heat exchanger profile. The ambient temperature conditions were controlled at 35 40 43 and 45 oC. The results of this study were found that heat exchanger profile had the highest average coefficient of performance and energy efficiency as 4.94 and 9.15 Btu/Wh which increased as 20.1% and 8.47% respectively when comparing with the normal working.

2560
To study the energy efficiency of air conditioners and hybrid air conditioners
To study the energy efficiency of air conditioners and hybrid air conditioners

This paper presents the results of tests to study the energy efficiency of air conditioners Split 9000 BTU test the air in normal operation and when the tune parts. of Evaporator units use DC power from solar energy. Power of the test in normal operating conditions the air power and average about 820 watts on system configuration and operation of Evaporator units. 645 air watts average power consumption can be reduced up to 175 watts of electricity equivalent to 21.34% of them compare the energy efficiency of the air conditioner from the label number 5 on the test. The energy efficiency of a 14.41 11.55 a 24.76% increase in energy efficiency

2558