จำนวน Repository ( 1139 )
ชุดสาธิตการผลิตไฟฟ้าด้วยพลังงานน้ำ
This project aims to create a series of demonstration power plant water. And the operation of the circuit Inverter split by the end of demonstration runs as follows. Theory and documents relating to the source of electrical power water power the working principle of the circuit. Inverter the principle of integrated battery charger main circuit voltage VDC LED LED SMD (Surface-Mounted-Device) a voltmeter. Ammeters digital LCD display couples. Make plans to offer advisors the project approved. Design demonstration kit Equipment supply and assembly Assembly and demonstration the production of electricity from hydropower 220 VAC test run is a series of demonstrations to generate electricity from water power to 220 VAC storage performance voltage and current output. And analyze the results of the operation of the demonstration production of electricity from hydropower 220 VAC and conclusions in this chapter are the results of the experiment demonstrated the production of electricity from hydropower and the conclusion of the trial in order to be used. effectiveness of the objectives of the experimental procedure the results can not load a load test. Test kits demonstration power plant and the demonstration set to produce 220 volts for 25 minutes at a constant voltage. The electricity does not increase or decrease. Always works The term of office is fixed or reduced by the ratio of active power increases.
การพัฒนาอุปกรณ์สวมใส่เพื่อเก็บข้อมูลการเคลื่อนไหวของวัวโดยใช้เทคโนโลยี ไอโอที
This project presents the development of wearable device for logging cow behavior using IoT technology. This project aims to develop the device that can collect the cow’s behavior and to identify the current position of cow. The accelerometer and ultrasonic sensors are used to measure walking behavior and sitting behavior respectively. The current position of cow is measured by GPS module. The measured data will be shown and stored in IoT platform. According to the experiments the developed systems can measure the behavior properly with human acting as a cow. Moreover the developed system can show the current position of the cow and message when the cow is out of area. In the future it is planned to implement the developed system with the actual cow in real situation
ชุดจำลองการป้องกันการเกิดอัคคีภัยในห้องครัวผ่านแอพพลิเคชั่น
This project aims to create the model of fire protection system for the kitchen. The model installed of protection and notification systems was created by using the Google SketchUp program with a ratio of 1:10 from the real kitchen scale. According to the literature it was found that more than 50 % of the fire within the shelter occurred in a kitchen. The main causes are flame heat sparks and electrical equipment. The system was developed to detect flame gas and smoke by using infrared sensor (IR FLAME) and gas detection device (MQ-2). Arduino MEGA2560 is a central processor to control the device of the protection system. Node MCU is a data receiver with Arduino to display the average amount of gas flame through the Blynk application in real time and send notification via the Line application when the amount of either flame gas or smoke is greater than or equal to the specified quantity. Fire protection system is divided into 3 conditions: fire gas and smoke. In case of fire the sprinkler will be activated with class K extinguishers to extinguish fire. In gas leakage conditions ventilator will be activated to ventilate the gas leaks and the gas supply is cut off. For smoke condition the ventilator will be activated to ventilate the smoke out of the kitchen. The results of the experiment by using the method of dividing into 13 simulations in total. The system can detect the flame with 12 points 92% from 13 points. In case of gas a can of gas was used in all tests. Nine points of gas can detect with 69% of the total 13 points. The smoke detector can capture smoke with a large amount of smoke. There are a total of 13 tests that can capture 11 smoke points representing 84% of all 13 points.
ไส้กรองน้ำเซรามิคจากเถ้าอุตสาหกรรมเพื่อบำบัดน้ำเสียฟอกย้อม
This research studied the efficiencies of ceramic membrane filtration from industrial asphalt for dyeing wastewater treatment by forming a ceramic membrane in a diameter of 6 cm height of 2 cm. An appropriate proportion of industrial ashes: kaolin: sodium hydroxide solution mixed with sodium silicate solution was 46:18:36 at 800 ° C. For the properties analysis of ceramic membrane made from industrial ashes found that a shrinkage value compression resistance and density water absorption value and permeate flux were found 3 percents 0.6 Kilonewtons per cubic centimeter and 1.93 grams per cubic centimeter 45 percents 8.61 milliliters per square centimeter per minute respectively. Structural surface by a scanning electron microscopy was found that the porous inside of material was closely aligned together. Moreover precipitation of synthetic wastewater by using industrial ashes could help to increase the efficiencies of dyeing wastewater treatment. From the experiment it was found that the precipitation of synthetic wastewater with industrial ash was 94 percent filtration efficiency. On the other hand the efficiencies of synthetic wastewater treatment without precipitating of industrial ashes found only 69 percent. Moreover this research offers a new option for industrial wastes utilization.
การบําบัดน้ำเสียจากชุมชนด้วยระบบเอสบีอาร์ร่วมกับยางพื้นรองเท้า
This research has studied the treatment of municipal wastewater with shoe soles as a supporting media for Sequencing Batch Reactor. The objectives of this research were the conditions to for optimize growing Photosynthetic Bacteria (PSB) and understand the treatment efficiencies of municipal wastewater treatment with PSB in Sequencing Batch Reactor (SBR). Three types of shoe soles were applied in this research composed of rubber shoe soles neoprene and EVA and the control without shoe soles. The experimental factors included the essential parameters such as BOD COD SS MLSS MLVSS Phosphorus and Ammonia-Nitrogen. F/M Ratio was adjusted at 0.13 and hydraulic retention time (HRT) was at 5 days. The results indicated that the removal efficiencies of SBR with rubber shoe soles in terms of BOD COD SS phosphorus and ammonia-nitrogen were 87% 80% 94% 53% and 68% respectively. The removal efficiencies of SBR with Neoprene shoe soles in terms of BOD COD SS Phosphorus and Ammonia-Nitrogen were 89% 81% 95% 20% and 73%. The removal efficiencies of SBR with EVA shoe soles in terms of BOD COD SS phosphorus and ammonia-nitrogen were 91% 86% 95% 56% and 74%. The removal efficiencies of SBR without shoe soles in terms of BOD COD SS phosphorus and ammonia-nitrogen were 84% 79% 93% 86% and 67% respectively. The treated wastewater was rather clear low content of suspended solids and no malodor. From overall results the treatment of municipal wastewater by anaerobic sequencing batch reactor with different types of shoe soles was not significant for wastewater treatment efficiencies by anaerobic with any 3 types among of shoes soles can be efficiently applied for municipal wastewater treatment.